Creates channel(s) that use an IEPE force sensor to measure force or load. You must configure the physical channel(s) with TEDS information to use this VI. LabVIEW NXG does not support FPGA devices Not ...

Returns the reference values to be measured by a reference device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 4463 Calibration Adjustment Points.vi ...

Creates channel(s) that use a thermocouple to measure temperature. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Temperature-Thermocouple).vi ...

Creates channel(s) that use(s) a charge-based sensor to measure acceleration. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Acceleration-Accelerometer).vi ...

Creates a channel that uses an angular encoder to measure angular position. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with ...

Creates a channel that uses a linear encoder to measure linear position. With the exception of devices that support multi-counter tasks, you can create only one counter input channel at a time with this ...

Configures TDMS file logging for the task. To maximize performance and to minimize file size, DAQmx TDMS files store raw data and scaling information separately, and do not need defragmentation. Attempting ...

Associates TEDS information with the physical channel you specify. If you do not specify the filename of a data sheet in the virtual TEDS file input, this node attempts to find a TEDS sensor connected ...

Creates channel(s) that use an eddy current proximity probe to measure position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-EddyCurrentProxProbe).vi ...

Creates channel(s) to measure voltage. If the measurement requires the use of internal excitation or you need excitation to scale the voltage, use the Custom Voltage with Excitation measurement type for ...

Creates channel(s) to measure voltage RMS, the average (mean) power of the acquired voltage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel ...

Creates channel(s) to generate voltage. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AO-Voltage-Basic).vi :/lvdaqmx.chm::/DAQmx ...

FieldDAQ Multidevice Tasks NI-DAQmx 17.6 Manual NI-DAQmx 18.1 Manual NI-DAQmx 18.5 Manual NI-DAQmx 18.6 Manual NI-DAQmx 19.0 Manual NI-DAQmx 19.1 Manual NI-DAQmx 19.5 Manual NI-DAQmx 19.6 Manual NI-DAQmx ...

Reads one or more raw, 32-bit signed integer samples from a task. Use this instance with devices that use 32-bit signed integers as the internal representation of a sample. LabVIEW NXG does not support ...

Reads one or more raw, 16-bit unsigned integer samples from a task. Use this instance with devices that use 16-bit unsigned integers as the internal representation of a sample. LabVIEW NXG does not support ...

Returns the reference voltage values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get ...

Creates channel(s) that use a Wheatstone bridge to measure torque. Use this instance with sensors whose specifications do not provide a polynomial for scaling or a table of electrical and physical values. ...

Returns the reference values to be used by a reference device to create a reference signal. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9251 Calibration ...

Returns the reference voltage values to be measured by a reference device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Get 9263 Calibration Adjustment ...

Updates power up states for digital physical channels. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Set Power Up States (Digital).vi :/lvdaqmx.chm::/DAQmx ...