Filtered Results

The NI-9866 has one full-featured LIN port that is isolated from the other modules in the system. The port has a LIN controller that is fully compliant with the LIN 1.3/2.0/2.1/2.2 Specification. The port ...

This document explains how to connect to the NI-9866 . Note Before you begin, read the NI-9866 Safety, Environmental, and Regulatory Information document on ni.com/manuals and complete the software and ...

Dimensions Visit ni.com/dimensions and search by module number. Weight Approx. 144 g (5.0 oz) Parent topic: NI-9866 Specifications

Power consumption from chassis 1 W maximum (active mode) Thermal dissipation (at 70 °C ) 1.25 W maximum (active mode) Parent topic: NI-9866 Specifications

Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications ...

Caution Observe all instructions and cautions in the user documentation. Using the product in a manner not specified can damage the product and compromise the built-in safety protection. Attention Suivez ...

This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: IEC 61010-1, EN 61010-1 UL 61010-1, CSA C22.2 No. ...

Connect only the voltages that are within these limits: Supply voltage range (Vsup) +8 V DC to +18 V DC Maximum voltage Port-to-COM -40 V DC to +40 V DC maximum, Measurement Category I Isolation Port-to-earth ...

To meet these specifications, you must panel mount the system. Operating vibration Random 5 g RMS , 10 Hz to 500 Hz Sinusoidal 5 g , 10 Hz to 500 Hz Operating shock 30 g , 11 ms half sine;

The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.

Showing 1-10 of 38 results
1 of 4 pages