The following items are known issues in NI Measurements Live Support Files.
ID | Known Issue | |||||
---|---|---|---|---|---|---|
716129 Return | The Current-Voltage Analyzer IV curve stops prematurely at the forward bias voltage instead of the user-selected voltage range. Solution: Update your NI ELVIS III to the LabVIEW 2018 ELVIS III Toolkit SP2 or later.
| |||||
723987 Return | An output delay occurs under certain conditions for the Logic Analyzer and Pattern Generator. When the duty cycle of an output signal is set to 100%, an output delay of up to 6 seconds. Solution: Update your NI ELVIS III to the LabVIEW 2019 ELVIS III Toolkit.
| |||||
735616 Return | Channel 1 and Channel 2 of the Function and Arbitrary Waveform Generator (FGEN) become unsynchronized after changing waveform parameters while running the FGEN soft front panel. Workaround: N/A.
| |||||
698572 Return | Logic Analyzer graph only shows 10 lines on macOS. This is currently a limitation of LabVIEW in macOS. Workaround: N/A.
| |||||
698535 Return | Logic Analyzer TDMS file export fails. The Logic Analyzer allows you to export TDMS files, but currently only CSV files are supported.
| |||||
698001 Return | Screen capture does not capture data when using the Bode Analyzer or Current-Voltage Analyzer in Safari. The first time the screen capture button (camera icon) is pressed in the Bode Analyzer or Current-Voltage Analyzer SFP (Soft Front Panel) in Safari, no data is collected.
| |||||
698303 Return | Oscilloscope analog edge trigger switches between rising and falling edge for noisy input signals. The analog trigger may activate on a rising edge when set to trigger on a falling edge and vice versa in the Oscilloscope SFP when measuring a noisy signal.
| |||||
691820 Return | Currently Unicode characters are not supported in custom waveform filenames. When attempting to load a custom waveform file in an SFP, the file will fail to load silently. Workaround: Remove Unicode characters from the filename.
| |||||
698274 Return | Failed to connect to an NI ELVIS III in Safari 11.0. Measurements Live is only supported in Safari 11.1 and later. Workaround: Update Safari to 11.1 or later.
|