NI Switch Replacement Relays

Overview

Many NI Switch modules or devices offer replacement relay options for broken or failed relays. If you are trying to repair or replace a relay on your NI Switch this document provides descriptions, part numbers, and vendor information to achieve these tasks.

Contents

Using this Switches Replacement Relay Guide

This guide is intended to cover replacement relays designed for use with NI Switches. It does not explicitly cover replacement parts for other NI product families such as DAQ. HSDIO, C Series, or reconfigurable I/O (formerly R Series). It also does not cover legacy or End of Life (EOL) parts or products.

 

How to Replace a Relay on Your Switch

If a relay on your NI Switch is broken or has failed you will need to perform the following tasks to replace it.

  1. Identify the correct replacement relay for your module or device. See the NI Replacement Relays and Manufacturer Part Numbers for relay orderable part numbers.
  2. Once you have the correct replacement relay, navigate to the NI-Switch Help. If you have installed NI-Switch on your system, the NI-Switch Help can be found in the <National Instruments>\NI-SWITCH\NI-SWITCH Documentation folder, or the NI-Switch Help can be found online
  3. In the NI-Switch Help you will find guidance on replacing your relay by navigating to NI Switches Help>>Devices>><Model Number>>>Relay Replacement. Here you will find a step-by-step guide on how to replace relays on your switch module. 

For example, a step-by-step guide on how to replace a relay in the NI PXIe-2526 can be found by navigating to NI Switches Help>>Devices>>NI PXIe-2526>>Relay Replacement

 

NI Replacement Relays and Manufacturer Part Numbers

Use this table to quickly identify the replacement relay part number for NI Switch modules and devices.
Switch Model Relay Type NI Orderable
Part Number
Manufacturer
Part Number
2510, 2522, 2523, 2737, 2738, 2739 Electromechanical 781089-10 Tyco Electronics 5-1462039-8
2520 Electromechanical 782460-10 Tyco Electronics IMB02CTS (1462041-5)
2521, 2524, 2525, 2526 Electromechanical 782461-10 Tyco Electronics 1462043-6
25271, 25681, 25691 Electromechanical 779356-01 AXICOM (Tyco Electronics) IM42GR (3-1462037-1)
Electromechanical 782051-01 AXICOM (Tyco Electronics) IM42PGR (5-1462039-7)
2564 Electromechanical 780262-01 Fujitsu JY-5H-K
2529 Electromechanical N/A Aromat (NAiS) AGQ210A4H
2565 Electromechanical 777880-01 Aromat (NAiS) DSP1a-DC5V
2530B Reed N/A Coto 9012-05-11
2531, 2532, 2532B Reed N/A Meder CRR05-1A
2566 Electromechanical N/A Aromat (NAiS) TQ2SA-5V
25701 Electromechanical - Through-Hole Mount 781678-01 AXICOM (Tyco Electronics) IM42PNS (7-1462039-8)
Electromechanical - Surface Mount 779356-01 AXICOM (Tyco Electronics) IM42GR (3-1462037-1)
2571 Electromechanical 781678-01 AXICOM (Tyco Electronics) IM42PNS (7-1462039-8)
25751,2 Electromechanical 780386-01 OMRON G6KU_2F-Y
Electromechanical 779356-01 AXICOM (Tyco Electronics) IM42GR (3-1462037-1)
Electromechanical 782051-01 AXICOM (Tyco Electronics) IM42PGR (5-1462039-7)
2576 Electromechanical 780383-01 OMRON G6JU-2P-Y DC4.5
2584 Reed N/A Coto Technology 9104-05-11
2585. 2586 Electromechanical N/A Potter & Brumfield (Tyco Electronics) RTB14005F (2-1419108-4)
27203, 27223, 27253, 27273 Reed 781451-10 Coto 9117-0001
Reed 786914-01 Standex-Meder UMS05-BV51101
2810, 2811, 2812, 2813, 2814 Electromechanical - Safety 781089-10 Tyco Electronics 5-1462039-8
Reed 781450-10 Meder MS05-BV50980
28153, 28163, 28173 Electromechanical - Safety 781089-10 Tyco Electronics 5-1462039-8
Reed 781451-10 Coto 9117-0001
Reed 786915-01 Standex-Meder UMS05-BV51338
2833, 2834 Electromechanical - Safety 781089-10 Tyco Electronics  5-1462039-8
Electromechanical 781678-01 AXICOM (Tyco Electronics) IM42PNS (7-1462039-8)

1 The IM42GR and IM42PGR relays are drop in replacements. Some switch model revisions were built using different relays. Contact NI to find out which relay was used on a specific device.
2 The G6KU_2K-Y can be used with the 2575 but is not a drop in replacement for the other relays listed as it is only rated for 30W. Some switch model revisions were built using different relays, contact NI to find out which relay was used on a specific device.

3 Some switch model revisions were built using different relays. Contact NI to find out which relay was used on a specific device.

 

Ordering Information

For more information on any of the listed NI orderable parts, please visit http://www.ni.com/contact-us/ to contact an NI representative. NI orderable parts listed in this guide without a product page can still be purchased by contacting NI.

For parts with a manufacturer part number, please contact the manufacturer or their vendors for further information about the product and purchasing.  Manufacturer part numbers represent functionally equivalent replacements that are currently available from the specified manufacturer. This may differ from the part found on your device, module, cable or accessory as NI continuously revises and improves their products.

Some parts are custom made for NI or are common parts in industry, and do not have orderable part numbers. Please use the specifications provided to find an appropriate part.

 

Was this information helpful?

Yes