The following items are notable issues fixed between the release of LabVIEW Communications System Design Suite 4.0 and LabVIEW Communications System Design Suite 5.0, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of LabVIEW Communications System Design Suite 5.0.

Bug Number

Legacy ID

Description

Details

90378 728092

Dropping a large number of unplaced FPGA devices in SystemDesigner can cause a hang.

Attempting to drop a large number of FPGA (USRP RIO or FlexRIO) devices in SystemDesigner, such as using the Unplaced Live Hardware>>All menu, can fail or cause a hang.

Workaround:

Drop the FPGA hardware items one by one.

Reported Version:

LabVIEW Communications System Design Suite 3.1

Resolved Version:

LabVIEW NXG 5.0

Added:

May 16, 2019

212294 745363

When debugging a LabVIEW Communications Real-Time Target, the dialog indicating a target reboot will not disappear if the application name has a space.

If trying to debug an application which has spaces in the name on a LabVIEW Communications Real-Time Target, the dialog indicating that the target is rebooting after deployment will not clear.

Workaround:

Remove any spaces from the name of the application document.

Reported Version:

LabVIEW Communications System Design Suite 4.0

Resolved Version:

LabVIEW Communications System Design Suite 5.0

Added:

Nov 1, 2019

184305 741504

Changing the System Description of a Real-Time Target in SystemDesigner would not update the text field.

Workaround:

There is currently no known workaround for this issue.

Reported Version:

LabVIEW Communications System Design Suite 3.1

Resolved Version:

LabVIEW Communications System Design Suite 5.0

Added:

May 15, 2020

SaltStack Critical Vulnerabilities CVE-2020-11651, CVE-2020-11652

The LabVIEW LabVIEW Communications System Design Suite 5.0 is affected by SaltStack security vulnerabilities CVE-2020-11651 and CVE-2020-11652.

Workaround:

Update to LabVIEW LabVIEW Communications System Design Suite 5.0.1.

Reported Version:

LabVIEW Communications System Design Suite: 5.0

Resolved Version:

LabVIEW Communications System Design Suite: 5.0.1

Added:

May 18, 2020

Additional Patch Information

These patches currently do not have any special instructions.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).