Important! After updating this Intel® Manageability Firmware, you can NOT downgrade the Intel® Manageability Firmware to previous version.

Please reference the readme file contained within the zip file to complete the Intel ® Manageability Firmware Update.

Installation Instructions

 

  1. Obtain a USB flash drive that may be overwritten if necessary.
  2. Convert the USB flash drive into a bootable device capable of booting DOS by running the "CreateUSBUtilityDisk.exe".
  3. Download the INTEL-SA-00075 UNPROVISIONING TOOL and follow the instruction to unprovision Intel® AMT on your controller.
  4. Insert the USB flash drive into your controller. Set up your controller to boot first from this USB flash drive using the following procedure:
    • While the controller boots, press DEL to enter the BIOS Setup Utility (note all changes made, they may need to be reset after Intel® Manageability Firmware update is completed)
    • Navigate to LabVIEW RT >> Boot Configuration and ensure that the Windows/Other OS is set. If you changed anything press F10 >> Yes >> Enter to save and reboot
    • (if needed) While rebooting, press DEL to enter the BIOS Setup Utility again.
    • Navigate to Advanced >> SATA Configuration >> SATA Mode Selection and select IDE
    • Navigate to Advanced >> USB Configuration and enable Legacy USB Support
    • Navigate to Advanced >> USB Configuration >> Mass Storage Devices and select Auto
    • Navigate to Boot >> Hard Drive BBS Priorities and move USB to the top of the list (Boot Option #1)
    • Navigate to Boot >> Boot Option #1 and make sure USB is at the top of the list
    • Press F10 >> Yes >> Enter to save and reboot
  5. Once the controller boots into DOS, follow the onscreen instructions in order to flash your Intel® Manageability Firmware.
  6. Once the system starts the Intel® Manageability Firmware update process, be sure to let the program complete or you will corrupt the system and it will not boot.
  7. Once the program is finished, remove the USB flash drive and reboot the controller.
  8. If a problem occurs during the flash, contact National Instruments technical support for assistance.