Table Of Contents

Set Calibration Axis (Set Calibration Axis - Reference Points) (G Dataflow)

Last Modified: June 25, 2019

Assigns coordinate system information to a calibration template image.

Use this instance when the origin of the calibration axis is outside of the image.

connector_pane_image
datatype_icon

calibrated image in

Reference to the template image to use for calibrating your system.

datatype_icon

pixel coordinates

Coordinates of 3 reference points in the image, in pixels.

datatype_icon

X

X-coordinate of the point.

datatype_icon

Y

Y-coordinate of the point.

datatype_icon

real-world coordinates

Corresponding locations of the 3 specified pixel coordinates in the real world.

datatype_icon

X

X-coordinate of the point.

datatype_icon

Y

Y-coordinate of the point.

datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

calibrated image out

Reference to the output image.

datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application