Table Of Contents

Adding and Configuring an SLSC device

Last Modified: June 15, 2020

Use SLSC devices to introduce signal conditioning and fault insertion into a real-time testing scheme.

  1. Launch the VeriStand Editor.
  2. In the Project Files pane, double-click a system definition file (.nivssdf). System Explorer opens.
  3. Click Targets»Controller»Hardware»SLSC in the configuration tree.
  4. Right-click SLSC and click Add SLSC Chassis.
  5. In the Add SLSC Chassis dialog box, use the Connect with drop-down to specify whether to connect to the chassis using the chassis name or the host name or IP address.
  6. Enter the chassis name, host name, or IP address.
  7. Enter a Username and Password for the engine to log into the SLSC chassis.
    spd-note-note
    Note  

    Entering a user name and password removes the requirement for custom devices to separately log into the SLSC chassis. If the credentials are incorrect when the engine attempts to log into the SLSC chassis, VeriStand will undeploy the system definition. By default, the user name is anonymous and the password left empty.

  8. Click OK.
  9. In the configuration tree, navigate to SLSC Chassis»Modules under your SLSC chassis.
  10. Use the drop-down menus under SLSC Modules Settings to select the modules in each of the chassis slots.
  11. Save the system definition file.