Table Of Contents

Acknowledge Alarm (Single)

Version:
Last Modified: August 29, 2019

Acknowledges an active alarm instance on the server.

An alarm instance remains active until you acknowlege and clear it. Typically, the application that sets the alarm clears it when the condition(s) that triggered the alarm no longer exist. An operator must acknowledge the alarm in the user interface or call this VI.

Use Query Alarms to find alarm instances you want to acknowledge.

spd-note-note
Note  

SystemLink Cloud does not support this VI.

alarm in

Active alarm instance you need to acknowledge.

note

Information you want to include about the alarm acknowledgement.

force clear alarms

A Boolean that determines whether to clear alarms without waiting for the application that set the alarms to do it.

The default is False.

error in

Error conditions that occur before this VI runs. The VI responds to this input according to standard error behavior.

alarm out

Active alarm instance you acknowledged.

error out

Error information. This VI produces this output according to standard error behavior.