    You can connect floating and grounded input signals to the FieldDAQ device. Make sure that devices you connect to the FieldDAQ device are compatible, as listed in the FD-116xx Specifications.

    The FD-116xx provides an IEPE excitation current for each channel to measure the IEPE sensors. Typical IEPE sensors have a case that is electrically isolated from the IEPE electronics. As a result, connecting the sensor to the FD-116xx results in a floating connection even though the case of the sensor is grounded.

    • Floating Signal Sources

      Figure 1. Connecting Floating Signal Sources to the FieldDAQ Device
    • Grounded Signal Sources—To ensure proper operation, make sure the voltage on the AI+ and AI- connections adhere to the channel-to-earth ground safety voltage specifications listed in the FD-116xx Specifications.

      Figure 2. Connecting Grounded Signal Sources to the FieldDAQ Device