These specifications apply to the PXI-4110 with APS-4100 Auxiliary Power Supply and the PXI-4110 without auxiliary power supply.
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
Specifications are valid under the following conditions unless otherwise noted.
The following table and figure illustrate the voltage and current source ranges of the PXI-4110.
Channel | DC voltage | Isolation[2] | DC current (power) | |||
---|---|---|---|---|---|---|
Auxiliary power | Internal power | |||||
20 mA range | 1 A range | 20 mA range | 1 A range | |||
0 | 0 V to +6 V | N/A | N/A | 1 A (6 W) | N/A | 1 A (6 W) |
1 | 0 V to +20 V | 60 VDC, CAT I | 20 mA | 1 A (20 W) | 20 mA | 100 mA (2 W)[3] |
2 | 0 V to -20 V | 60 VDC, CAT I | 20 mA | 1 A (20 W) | 20 mA | 100 mA (2 W)[3] |
Channel | Range | Resolution | Accuracy ± (% of voltage + offset) | |
---|---|---|---|---|
1 year 23 °C ± 10 °C | Tempco/°C[4] 0 °C to 55 °C | |||
0 | +6 V | 0.12 mV | 0.05% + 4 mV | 0.005% + 0.3 mV |
1 | +20 V | 0.40 mV | 0.05% + 10 mV | 0.005% + 1 mV |
2 | -20 V | 0.40 mV | 0.05% + 10 mV | 0.005% + 1 mV |
Channel | Range[6] | Resolution | Accuracy ± (% of current + offset) | |
---|---|---|---|---|
1 year 23 °C ± 10 °C | Tempco/°C[7] 0 °C to 55 °C | |||
0 | 1 A | 0.02 mA | 0.15% + 4 mA | 0.02% + 0.2 mA |
1 and 2 | 20 mA | 0.40 μA | 0.15% + 60 μA | 0.01% + 3 μA |
1 A | 0.02 mA | 0.15% + 4 mA | 0.02% + 0.2 mA |
Channel | Range | Resolution | Accuracy ± (% of voltage + offset) | |
---|---|---|---|---|
1 year 23 °C ± 10 °C | Tempco/°C[] 0 °C to 55 °C | |||
0 | +6 V | 0.06 mV | 0.05% + 4 mV | 0.005% + 0.2 mV |
1 | +20 V | 0.20 mV | 0.05% + 5 mV | 0.005% + 0.5 mV |
2 | -20 V | 0.20 mV | 0.05% + 5 mV | 0.005% + 0.5 mV |
Channel | Range | Resolution | Accuracy ± (% of current + offset)[10] | |
---|---|---|---|---|
1 year 23 °C ± 10 °C | Tempco/°C[11] 0 °C to 55 °C | |||
0 | 1 A | 0.01 mA | 0.15% + 4 mA | 0.02% + 0.2 mA |
1 and 2 | 20 mA | 0.20 μA | 0.15% + 35 μA | 0.01% + 3 μA |
1 A | 0.01 mA | 0.15% + 4 mA | 0.02% + 0.2 mA |
Channel | Auxiliary power | Internal power | ||||||
---|---|---|---|---|---|---|---|---|
Rise time[13] | Fall time[14] | Rise time[13] | Fall time[14] | |||||
Full load | No load | Full load | No load | Full load | No load | Full load | No load | |
0 | <1 ms | <1 ms | <1 ms | <25 ms | same as auxiliary power | |||
1 and 2 | <1 ms | <1 ms | <2 ms | <56 ms | <20 ms | <10 ms | <15 ms | <56 ms |
|
|||||||||||||||||||||
|
Channel | RMS normal-mode voltage (20 Hz to 20 MHz) | RMS normal-mode current (20 mA into 500 Ω load)[16] |
---|---|---|
0 | <1.5 mV | <8 μA |
1 and 2 | <1 mV | <8 μA (<3 μA for 20 mA range) |
The following figure illustrates accuracy specification derating as a function of output current for the PXI-4110.
Transient response |
Recovers to <0.1% of voltage range within 50 μs after a change in load current from 50% to 100% of current range, typical. |
|
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
|
|||||||||
|
Isolation voltage, channels 1- and 2-to-earth ground |
60 VDC, CAT I, verified by dielectric withstand test, 5 s, continuous |
PXI power requirement |
10 W at 5 V, 1 W at 3.3 V, 6 W at 12 V, 3 W at -12 V, typical |
Auxiliary power source (optional, channels 1 and 2 only) input requirements |
11 VDC to 15.5 VDC, 5 A max, typical |
Dimensions |
3U, one-slot, PXI/cPCI module; 2.0 cm × 13.0 cm × 21.6 cm (0.8 in. × 5.1 in. × 8.5 in.), nominal |
||||||
Weight |
323 g, typical |
||||||
|
|
Maximum altitude |
2,000 m (at 25 °C ambient temperature) |
Pollution Degree |
2 |
This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use:
For UL and other safety certifications, refer to the product label or the Online Product Certification section.
For EMC declarations, certifications, and additional information, refer to the Online Product Certification section.
This product meets the essential requirements of applicable European Directives, as follows:
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column.
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.