This document lists specifications for the PXI-8516 2-port LIN interface module.
Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty.
Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.
Trigger lines |
7 input/output |
Clock lines |
1 input/output |
I/O compatibility |
TTL |
Power-on state |
Input (High-Z) |
Response |
Rising edge triggers |
Transceiver[1] |
ATMEL ATA6620 or ATA6625 |
Max baud rate |
20 kbps |
Min baud rate |
2.4 kbps |
Bus Power Required |
+8 V to +18 V |
Operating temperature |
0 °C to 55 °C |
Storage temperature |
-20 °C to 70 °C (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.) |
Operating humidity |
10% to 90% RH, noncondensing |
Storage humidity |
5% to 95% RH, noncondensing (Tested in accordance with IEC-60068-2-56.) |
Maximum altitude |
2000 m |
Pollution Degree (IEC 60664) |
2 |
Indoor use only.
Operating shock |
30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC-60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) |
Operating |
5 Hz to 500 Hz, 0.3 grms |
Nonoperating |
5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC-60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) |
|
|||||||
|
Measurement Category I is for measurement performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
For UL and other safety certifications, refer to the product label or the Product Certifications and Declarations section.
This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use:
This product meets the essential requirements of applicable European Directives, as follows:
Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for NI products, visit ni.com/product-certifications, search by model number, and click the appropriate link.
NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
For additional environmental information, refer to the Commitment to the Environment web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document.
At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee.