Table Of Contents

MuxValue

Last Modified: February 7, 2020

Value of the data multiplexer for this dynamic subframe (raw unsigned integer).

When the data multiplexer contains this value on the bus, the Dynamic Signals exist in the frame. Only one subframe is transmitted at a time in the frame.

This property is required. If the property does not contain a valid value, and you create an XNET session that uses this subframe, the session returns an error.

Data type: datatype_icon

Long Name: Multiplexer Value

Class: XNET Subframe

Permissions: Read/Write

There is also a multiplexer value for a signal object as a read-only property. It reflects the value set on the parent subframe object.

To ensure that this property contains a valid value, you can do one of the following:

  • Use a database file (or alias) to create the session. The file formats require a valid value in the text for this property.
  • Set a value in LabVIEW using the property node. This is needed when you create your own in-memory database (:memory:) rather than use a file. The property does not contain a default in this case, so you must set a valid value prior to creating a session.

Where This Property Is Available:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application