Table Of Contents

Get Terminal Name (G Dataflow)

Version:
    Last Modified: December 19, 2017

    Returns the fully-qualified name of the specified signal.

    The fully-qualified signal name is helpful when you want to automatically route signals in a multi-segment chassis.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from Initialize With Options .

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    signal

    Signal to query.

    Name Description
    Start Trigger Queries the Start Trigger.
    Script Trigger Queries a Script Trigger.
    Marker Event Queries a Marker Event.
    Ref Clock Queries the Reference Clock.
    Started Event Queries the Started Event.
    Done Event Queries the Done Event.
    Configuration List Step Trigger Queries the Configuration List Step Trigger.
    Configuration Settled Event Queries the Configuration Settled Event.
    datatype_icon

    signal identifier

    Script Trigger or Marker Event to configure. This input is useful when you set the signal input to Script Trigger or Marker Event. Otherwise, set this input to None.

    Name Description
    scriptTrigger0 Specifies Script Trigger 0.
    scriptTrigger1 Specifies Script Trigger 1.
    scriptTrigger2 Specifies Script Trigger 2.
    scriptTrigger3 Specifies Script Trigger 3.
    marker0 Specifies Marker 0.
    marker1 Specifies Marker 1.
    marker2 Specifies Marker 2.
    marker3 Specifies Marker 3.
    None Does not export a signal.
    datatype_icon

    session out

    Reference to your instrument session passed to the next node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    terminal name

    Fully-qualified string.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application

    Hardware Support:

    This node supports the following hardware:

    • PXI/PXIe-5650/5651/5652, PXIe-5653/5654/5654 with PXIe-5696
    • PXIe-5673E
    • PXIe-5820/5840


    Recently Viewed Topics