Table Of Contents

Perform Thermal Correction (G Dataflow)

Version:
    Last Modified: December 19, 2018

    Corrects for temperature variations while acquiring the same signal for extended periods of time in a continuous acquisition.

    spd-note-note
    Note

    You cannot call this node if your device is operating in RF list mode.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from Initialize With Options .

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    session out

    Reference to your instrument session passed to the next node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Frequency of Node Use

    NI-RFSA internally acquires the temperature every time you initiate an acquisition. If you are performing a continuous acquisition, National Instruments recommends calling this node once every 10 minutes in a stable temperature environment to periodically update temperature calibration. If the ambient temperature varies, call this node more frequently.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application

    Hardware Support:

    This node supports the following hardware:

    • PXIe-5663E/5665/5667/5668
    • PXIe-5693/5694
    • PXIe-5840


    Recently Viewed Topics