Table Of Contents

Get Self Calibration Last Temp (G Dataflow)

Version:
    Last Modified: December 19, 2018

    Returns the temperature, in degrees Celsius, at the last successful self-calibration.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from Initialize With Options .

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    self cal step 2

    Self-calibration step to query for the last successful self-calibration temperature data.

    spd-note-note
    Note

    For the PXIe-5644/5645/5646, you must select Image Suppression for the sel cal step input.

    Name Description
    Preselector Alignment Selects the Preselector Alignment self-calibration step.
    Gain Reference Selects the Gain Reference self-calibration step.
    IF Flatness Selects the IF Flatness self-calibration step.
    Digitizer Self Cal Selects the Digitizer Self Cal self-calibration step.
    LO Self Cal Selects the LO Self Cal self-calibration step.
    Amplitude Accuracy Selects the Amplitude Accuracy self-calibration step.
    Residual LO Power Selects the Residual LO Power self-calibration step.
    Image Suppression Selects the Image Suppression self-calibration step.
    Synthesizer Alignment Selects the Synthesizer Alignment self-calibration step.
    DC Offset Selects the DC Offset self-calibration step.
    datatype_icon

    session out

    Reference to your instrument session passed to the next node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    datatype_icon

    temperature

    Temperature, in degrees Celsius, at the last self-calibration.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application

    Hardware Support:

    This node supports the following hardware:

    • PXIe-5601/5603/5605/5606 (external digitizer mode)
    • PXIe-5644/5645/5646
    • PXIe-5663E/5665/5667/5668
    • PXIe-5820/5840


    Recently Viewed Topics