Table Of Contents

Create Configuration List Step (G Dataflow)

Version:
    Last Modified: December 19, 2018

    Creates a new configuration list step in the configuration list for RF list mode specified by the Active Configuration List property.

    When you create a configuration list step, a new instance of each property specified by the configuration list properties is created. Configuration list properties are specified when you create a configuration list.

    connector_pane_image
    datatype_icon

    session in

    Instrument session obtained from Initialize With Options .

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    set as active step

    Boolean value that specifies whether this step is the active step for the active configuration list.

    spd-note-note
    Note

    If you set this input to False, you can select the active configuration list step using the Active Configuration List Step property.

    True The step is the active configuration list step.
    False The step is not the active configuration list step.

    Default: True

    datatype_icon

    session out

    Reference to your instrument session passed to the next node.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
    Search within the programming environment to access the following installed examples:
    • RFSA List Mode Frequency and Power Sweep (Power Triggered)
    • RFSA List Mode Frequency and Power Sweep (Timer Triggered)
    • RFSA Lost Mode Open Loop Synchronization with RFSG (Multiple Waveforms)

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application

    Hardware Support:

    This node supports the following hardware:
    • PXIe-5644/5645/5646
    • PXIe-5663E/5665/5667
    • PXIe-5820/5840


    Recently Viewed Topics