Configures a Script Trigger for level triggering, setting the trigger source and active level.
The waveform generator must not be in the Generating state when you call this node.
Handle that identifies your instrument session previously allocated by Initialize With Channels.
Script Trigger used for triggering.
Default: Script Trigger 0
Trigger source the waveform generator uses.
Active level for the desired trigger.
Name | Value | Description |
---|---|---|
High Level | 0 | The high level is the active level. |
Low Level | 1 | The low level is the active level. |
Default: High Level
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Standard Error Behavior
Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.
Default: No error
Reference to your instrument session to wire to the next node.
Error information.
The node produces this output according to standard error behavior.
Standard Error Behavior
Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.
Where This Node Can Run:
Desktop OS: Windows
FPGA: Not supported
Web Server: Not supported in VIs that run in a web application