Specifies if a task acquires or generates a finite number of samples or if it continuously acquires or generates samples.
For an analog input task with a Reference Trigger, you must set this property to Finite Samples even though the task runs continuously until the Reference Trigger occurs.
Data type:
Name | Value | Description |
---|---|---|
Finite Samples | 10178 | Acquire or generate a finite number of samples. |
Continuous Samples | 10123 | Acquire or generate samples until you stop the task. |
Hardware Timed Single Point | 12522 | Acquire or generate samples continuously using hardware timing without a buffer. Hardware timed single point sample mode is supported only for the sample clock and change detection timing types. |
Where This Property Is Available:
Desktop OS: Windows
FPGA: Not supported
Web Server: Not supported in VIs that run in a web application