Queries the status of the task and indicates if it completed execution. Use this node to ensure that the specified operation is complete before you stop the task.
task in is the name of the task that the operation applies.
error in describes error conditions that occur before this node runs. This input provides standard 'error in' functionality.
task out is a reference to the task after this node runs.
task done? indicates if the measurement or generation completed.
error out contains error information. If error in indicates that an error occurred before this node ran, error out contains the same error information. Otherwise, error out describes the error status that this node produces.
Where This Node Can Run:
Desktop OS: Windows
FPGA: LabVIEW NXG does not support FPGA devices
Web Server: Not supported in VIs that run in a web application