Table Of Contents

ni579x Store Characterization Data (EEPROM) (G Dataflow)

Version:
    Last Modified: April 3, 2018

    Stores headers and per-channel characterization data in the on-device EEPROM.

    spd-note-notice
    Notice

    This node erases existing data in the EEPROM. Contact National Instruments before using this node.

    connector_pane_image
    datatype_icon

    Register Bus

    Register Bus object created by ni579x Open and used as the session handle for the NI-579x Configuration nodes.

    datatype_icon

    EEPROM Calibration Header

    Header information describing the calibration sections.

    datatype_icon

    Device Data Header

    Header information describing the device characterization data sections.

    datatype_icon

    Characterization Data

    Characterization data for the specified channel.

    datatype_icon

    error in

    Error conditions that occur before this node runs.

    The node responds to this input according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Default: No error

    datatype_icon

    scope

    The EEPROM to read characterization data from. The only valid value is characterization data eeprom.

    datatype_icon

    EEPROM Header

    Header information for the entire EEPROM.

    datatype_icon

    start address

    The start offset of the data in the EEPROM.

    datatype_icon

    EEPROM Data Section

    The EEPROM can contain characterization data measured and calculated by the manufacturer (Factory Data), as well as data measured and calculated by the user (User Data).

    datatype_icon

    Register Bus (out)

    The Register Bus object created by ni579x Open and used as the session handle for the NI-579x Configuration nodes.

    datatype_icon

    error out

    Error information.

    The node produces this output according to standard error behavior.

    Standard Error Behavior

    Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

    error in does not contain an error error in contains an error
    If no error occurred before the node runs, the node begins execution normally.

    If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

    If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

    Where This Node Can Run:

    Desktop OS: Windows

    FPGA: Not supported

    Web Server: Not supported in VIs that run in a web application


    Recently Viewed Topics