Enables or disables auto-ranging on the channel specified.
Auto-ranging means that the sensor firmware determines the appropriate range for sensor operation. If you disable auto-ranging, specify the range using
Configure Range
.
error in
Error conditions that occur before this node runs.
The node responds to this input according to standard error behavior.
Many nodes provide an
error in
input and an
error out
output so that the node can respond to and communicate errors that occur while code is running. The value of
error in
specifies whether an error occurred before the node runs. Most nodes respond to values of
error in
in a standard, predictable way.
error in
does not contain an error
|
error in
contains an error
|
|
|
If no error occurred before the node runs, the node begins execution normally.
If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as
error out.
|
If an error occurred before the node runs, the node does not execute. Instead, it returns the
error in
value as
error out.
|
Default:
No error
channel name
Name of the channel you want to configure.
Default:
0
range auto enabled
Boolean value that specifies whether the
NI-568x
device automatically determines the optimal measurement range of power.
False is the only supported value for the
USB-5680.
True |
Auto-ranging is enabled. |
False |
Auto-ranging is not enabled. |
Default:
True
session out
Reference to your instrument session passed to the next node.
error out
Error information.
The node produces this output according to standard error behavior.
Many nodes provide an
error in
input and an
error out
output so that the node can respond to and communicate errors that occur while code is running. The value of
error in
specifies whether an error occurred before the node runs. Most nodes respond to values of
error in
in a standard, predictable way.
error in
does not contain an error
|
error in
contains an error
|
|
|
If no error occurred before the node runs, the node begins execution normally.
If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as
error out.
|
If an error occurred before the node runs, the node does not execute. Instead, it returns the
error in
value as
error out.
|
Where This Node Can Run:
Desktop OS: Windows
FPGA: Not supported
Web Server: Not supported in VIs that run in a web application
Hardware Support:
This node supports the following hardware:
-
USB-5680
-
USB-5681
-
USB-5683
-
USB-5684