Set DAQ Settings VI

Version:
Last Modified: August 28, 2020

Configures NI-DAQmx settings for the PXIe-6361 instrument that controls the position monitoring portion of the chamber.

These settings define the resolution and total points per sweep to be captured in Autonomous mode.

Session Handle in

Specifies the OTA session.

Resolution

Specifies the desired resolution of the sweep, in degrees. The value for this input is defined in the configuration file.

Number of Points

Specifies the number of points used for the test session. Use the mmWave OTA Validation Configurator to determine the number of points.

spd-note-note
Note  

A timeout may occur if the specified number of points is too high, as the software expects more triggers. If the specified number of points is too low, the grid will have missing points at the end of the sweep.

error in (no error)

Describes error conditions that occur before this node runs. This input provides standard error in functionality.

Session Handle out

Passes a reference of the OTA session to the next VI.

error out

Error information. This output provides standard error out functionality.