A timing source controls the execution of a
Timed Loop.
Open or create a VI that includes at least one
Timed Loop
on the diagram.
Add
Create Timing Source
to the diagram. Configure the type and rate of the timing source using the pull-down menus that appear.
Type
Description
Built-In
A timing source that controls a
Timed Loop
using an internal clock. You can choose from the following built-in timing sources:
1 kHz Clock—A clock that allows you to schedule a
Timed Loop
with millisecond resolution. By default, a
Timed Loop
uses the 1 kHz clock of the operating system as a timing source.
1 MHz Clock—A clock that allows you to schedule a
Timed Loop
with microsecond resolution. If the controller does not support microsecond resolution due to processor or operating system limitations, the 1 MHz clock is not available.
Note
You can also select a built-in timing source by selecting the
Timing Source
border node on the
Timed Loop
and choosing a timing source in the
Item
tab.
Software-Triggered
A timing source that triggers the start of a timed structure based on a software-defined event. You can use a software-triggered timing source for the following applications:
As a real-time-compatible event handler.
To notify a consumer
Timed Loop
when new data becomes available within a producer-consumer application.
For discrete event simulation.
Note
Use
Fire Software-Triggered Timing Source
to specify the number of ticks that elapse between each event.
Wire
timing source name
of
Create Timing Source
to
source in
on the
Timing Source
border node of any
Timed Loop