Table Of Contents

IviDigitizer Close (G Dataflow)

Last Modified: September 7, 2018

Closes the instrument I/O session. Destroys the instrument driver session and all of its properties. Deallocates any memory resources the driver uses.

spd-note-note
Note  

You must unlock the session before calling IviDigitizer Close Node.

spd-note-note
Note  

After calling IviDigitizer Close Node, you cannot use the instrument driver again until you call IviDigitizer Initialize Node or IviDigitizer Initialize With Options Node.

connector_pane_image
datatype_icon

error out

Error information.

The node produces this output according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.
datatype_icon

error in

Error conditions that occur before this node runs.

The node responds to this input according to standard error behavior.

Standard Error Behavior

Many nodes provide an error in input and an error out output so that the node can respond to and communicate errors that occur while code is running. The value of error in specifies whether an error occurred before the node runs. Most nodes respond to values of error in in a standard, predictable way.

error in does not contain an error error in contains an error
If no error occurred before the node runs, the node begins execution normally.

If no error occurs while the node runs, it returns no error. If an error does occur while the node runs, it returns that error information as error out.

If an error occurred before the node runs, the node does not execute. Instead, it returns the error in value as error out.

Default: No error

datatype_icon

instrument handle

The instrument handle that you obtain from the IviDigitizer Initialize Node or IviDigitizer Initialize With Options Node. The handle identifies a particular instrument session.

Default: None

Where This Node Can Run:

Desktop OS: Windows

FPGA: Not supported

Web Server: Not supported in VIs that run in a web application


Recently Viewed Topics