    You can configure your project channels with TEDS by selecting one or more channels and clicking the Scan for TEDS button.

    1. Hover over the channel and click Scan for TEDS . FlexLogger will scan all selected channels for any connected TEDS sensors. The following table lists the possible results of the Scan for TEDS action.
      Sensor State Result in FlexLogger
      TEDS sensor compatible with the channel is connected Channel is configured using data read from the TEDS scan. Previously configured channels will be overwritten by the TEDS sensor properties.
      No TEDS sensor is connected No changes occur. Channel(s) will retain their previous configuration.
      TEDS sensor is connected, but a sensor class read from TEDS is not supported by FlexLogger or the device Error appears on the channel(s). Resolve errors to run test.
      TEDS sensor is connected, but a sensor property read from TEDS is not supported by the device Error appears on the channel(s). Resolve errors to run test.
      TEDS sensor is connected, but data off the EEPROM is corrupted Error appears on the channel(s). Replace the TEDS sensor.
    2. (Optional) Compare channel configuration properties against the TEDS data, if necessary.
      1. Hover over the channel row to see the Configure gear .
      2. Click the gear to open the channel configuration dialog.
      3. In the channel configuration dialog, click the Edit icon on the Sensor Properties field to view the contents of the sensor EEPROM from the last scan.
      spd-note-note
      Note  

      Pasting a TEDS sensor channel configuration into a new channel will not automatically populate Sensor Properties with EEPROM contents. To ensure that the EEPROM contents are imported into the new channel, click the Scan for TEDS button.