Table 1. CompactDAQ Chassis
NI Product Model Name Notes
CompactDAQ Chassis cDAQ-9171
cDAQ-9174
cDAQ-9178
cDAQ-9179
cDAQ-9181
cDAQ-9184
cDAQ-9185 This chassis supports network synchronization using IEEE 802.1AS protocol. Refer to the Using Network Synchronization in Your Acquisition topic for more information.
cDAQ-9188
cDAQ-9188XT
cDAQ-9189 This chassis supports network synchronization using IEEE 802.1AS protocol. Refer to the Using Network Synchronization in Your Acquisition topic for more information.
cDAQ-9191
Table 2. C Series Modules
NI Product Model Name Notes
C Series Voltage Input Modules NI 9201
NI 9202
NI 9205
NI 9206
NI 9209
NI 9215
NI 9220
NI 9221
NI 9222
NI 9223
NI 9224
NI 9225
NI 9228
NI 9229
NI 9238
NI 9239
NI 9242
NI 9244
NI 9251
NI 9252 The NI 9252 module supports hardware filtering. Refer to the Reducing Signal Noise topic for more information.
C Series Voltage Output Modules NI 9262
NI 9263
NI 9264
NI 9269
C Series Current Input Modules NI 9203
NI 9208
NI 9227
NI 9246
NI 9247
NI 9253 The NI 9253 module supports hardware filtering. Refer to the Reducing Signal Noise topic for more information.
C Series Current Output Modules NI 9265
NI 9266
C Series Voltage and Current Input Module NI 9207
C Series Sound and Vibration Input Modules NI 9230
NI 9231
NI 9232
NI 9234
NI 9250
C Series Temperature Input Modules NI 9210
NI 9211
NI 9212
NI 9213
NI 9214
NI 9216 FlexLogger supports resistance measurements for the NI 9216.
NI 9217 FlexLogger supports resistance measurements for the NI 9217.
NI 9226 FlexLogger supports resistance measurements for the NI 9226.
C Series Universal Analog Input Modules NI 9218 For the NI 9218, all connectivity accessories must be configured in MAX in order to appear in your FlexLogger project.
NI 9219 FlexLogger supports resistance measurements for the NI 9219.
C Series Strain/Bridge Input Modules NI 9235
NI 9236
NI 9237
C Series Counter Input Module NI 9361 FlexLogger supports pull-up resistor functionality and input voltage threshold for the NI 9361.
C Series Digital Modules (serial digital I/O) NI 9375
  • The NI 9375 can only use one port (input or output) at a time in a project.
  • You cannot use parallel and serial modules together on the same FlexLogger project unless they are installed in separate cDAQ chassis.
NI 9403
NI 9425
NI 9426
NI 9476
NI 9477
NI 9478
C Series Digital Modules (parallel digital I/O) NI 9344 You cannot use parallel and serial modules together on the same FlexLogger project unless they are installed in separate cDAQ chassis.
NI 9401
NI 9402
NI 9411
NI 9421
NI 9422
NI 9423
NI 9435
NI 9436
NI 9437
NI 9472
NI 9474
NI 9475
NI 9481
NI 9482
NI 9485
C Series CAN and Vehicle Multiprotocol Interface Modules NI 9860 FlexLogger supports all compatible transceiver cables for the NI 9860 (TRC-8542, TRC-8543, and TRC-8546).
NI 9861
NI 9862
C Series LIN Interface Module NI 9866
Table 3. FieldDAQ Devices
NI Product Model Name Notes
Voltage Input Devices for FieldDAQ FD-11601 External powered sensor configuration is supported in FlexLogger.
FD-11603 Revision B and later of the FD-11603 supports hardware filtering. Refer to the Reducing Signal Noise topic for more information.
FD-11605
Sound and Vibration Input Devices for FieldDAQ FD-11634
Strain/Bridge Input Devices for FieldDAQ FD-11637 Revision B and later of the FD-11637 supports hardware filtering. Refer to the Reducing Signal Noise topic for more information.
Temperature Input Devices for FieldDAQ FD-11613
FD-11614

Note: FieldDAQ devices support network synchronization using IEEE 802.1AS protocol. Refer to the Using Network Synchronization in Your Acquisition topic for more information.

Note: FieldDAQ devices support hardware filtering. Refer to the Reducing Signal Noise topic for more information. (See Notes column for exceptions.)

Table 4. PXI Chassis
NI Product Notes
PXIe-1062Q FlexLogger does not support any module used in a PXI peripheral slot.
PXIe-1065
PXIe-1066DC
PXIe-1071
PXIe-1073
PXIe-1075
PXIe-1078
PXIe-1082
PXIe-1082DC
PXIe-1084
PXIe-1085 (12 GB/s and 24GB/s)
PXIe-1092
PXIe-1095

PXI Controllers

Supported embedded controllers must meet the minimum system requirements. Refer to the System Requirements section of the FlexLogger 2020 R3 Readme for more information.

Table 5. PXI Remote Control Modules
NI Product Notes
PXIe-8301
PXIe-8360
PXIe-8370
PXIe-8375
PXIe-8381
PXIe-8388
PXIe-8389
PXIe-8394
PXIe-8398
PXIe-8399
Table 6. PXI Modules
NI Product Model Name Compatible Accessories Notes
PXI Analog Input Modules PXIe-4300
  • TB-4300
  • TB-4300B
  • TB-4300C
PXIe-4302
  • TB-4302
  • RM-4302
  • TB-4302C
PXIe-4303
  • TB-4302
  • RM-4302
  • TB-4302C
PXIe-4304
  • TB-4304
  • RM-4304
PXIe-4305
  • TB-4304
  • RM-4304
PXIe-4309
  • TB-4309 (Mass Termination)
  • TB-4309 (Screw Terminal)
PXIe-4310
  • TB-4310
PXIe-4481
PXI Strain/Bridge Input Module PXIe-4330
  • TB-4330
  • RM-24999
PXIe-4331
  • TB-4330
  • RM-24999
PXIe-4339
  • TB-4339
  • TB-4339B
  • TB-4339C
  • RM-4339
PXI Displacement Input Module PXIe-4340
  • TB-4340
PXI Temperature Input Module PXIe-4353
  • TB-4353
  • TC-4353
PXIe-4357
  • TB-4357
FlexLogger supports resistance measurements for the PXIe-4357.
PXI Analog Output Module PXIe-4322
  • TB-4322
PXI Sound and Vibration Modules PXIe-4464
PXIe-4480 FlexLogger does not support the Charge measurement type.
PXIe-4492 FlexLogger automatically selects the Medium (100 Hz) data rate for the PXIe-449x . Using data rates between 1,000 Hz and 8,000 Hz with the PXIe-449x may cause delays when configuring channels.
PXIe-4496
PXIe-4497
PXIe-4498
PXIe-4499
PXI Vehicle Multiprotocol Interface Module PXIe-8510 (2-Port and 6-port)
  • TRC-8542
  • TRC-8543
  • TRC-8546
PXI CAN Interface Module PXI-8512 (1-port and 2-port) Must be used in a PXIe Hybrid Compatible slot of a supported PXI Express chassis. For additional information on PXI compatibility with PXI Express chassis, visit ni.com/r/pxicompatibility.
PXI LIN Interface Module PXI-8516
Note: The following synchronization considerations apply to PXI modules in FlexLogger:
  • FlexLogger supports PXI synchronization between modules in a chassis.
  • FlexLogger does not currently support synchronization between multiple chassis or other devices in the system.
Table 7. USB Devices
NI Product Model Name Notes
CAN Interface Devices USB-8502
LIN Interface Devices USB-8506

Recently Viewed Topics