Refer to the following table for a list of hardware devices FlexLogger supports.
Note
You can use supported hardware in FlexLogger without a network connection.
Table 1.
CompactDAQ Chassis
NI Product |
Model Name
|
Notes |
CompactDAQ Chassis
|
cDAQ-9171
|
—
|
cDAQ-9174
|
—
|
cDAQ-9178
|
—
|
cDAQ-9179
|
—
|
cDAQ-9181
|
—
|
cDAQ-9184
|
—
|
cDAQ-9185
|
This chassis supports network synchronization using IEEE 802.1AS protocol. Refer to the
Using Network Synchronization in Your Acquisition
topic for more information.
|
cDAQ-9188
|
—
|
cDAQ-9188XT
|
—
|
cDAQ-9189
|
This chassis supports network synchronization using IEEE 802.1AS protocol. Refer to the
Using Network Synchronization in Your Acquisition
topic for more information.
|
cDAQ-9191
|
—
|
Table 2.
C Series Modules
NI Product
|
Model Name
|
Notes
|
C Series Voltage Input Modules
|
NI 9201
|
—
|
NI 9202
|
—
|
NI 9205
|
—
|
NI 9206
|
—
|
NI 9209
|
—
|
NI 9215
|
—
|
NI 9220
|
—
|
NI 9221
|
—
|
NI 9222
|
—
|
NI 9223
|
—
|
NI 9224
|
—
|
NI 9225
|
—
|
NI 9228
|
—
|
NI 9229
|
—
|
NI 9238
|
—
|
NI 9239
|
—
|
NI 9242
|
—
|
NI 9244
|
—
|
NI 9251
|
—
|
NI 9252
|
The
NI 9252
module supports hardware filtering. Refer to the
Reducing Signal Noise
topic for more information.
|
C Series Voltage Output Modules
|
NI 9262 |
—
|
NI 9263
|
—
|
NI 9264
|
—
|
NI 9269
|
—
|
C Series Current Input Modules
|
NI 9203
|
—
|
NI 9208
|
—
|
NI 9227
|
—
|
NI 9246
|
—
|
NI 9247
|
—
|
NI 9253
|
The
NI 9253
module supports hardware filtering. Refer to the
Reducing Signal Noise
topic for more information.
|
C Series Current Output Modules
|
NI 9265
|
—
|
NI 9266
|
—
|
C Series Voltage and Current Input Module |
NI 9207
|
—
|
C Series Sound and Vibration Input Modules
|
NI 9230
|
—
|
NI 9231
|
—
|
NI 9232
|
—
|
NI 9234
|
—
|
NI 9250
|
—
|
C Series Temperature Input Modules
|
NI 9210
|
—
|
NI 9211
|
—
|
NI 9212
|
—
|
NI 9213
|
—
|
NI 9214
|
—
|
NI 9216
|
FlexLogger supports resistance measurements for the
NI 9216.
|
NI 9217
|
FlexLogger supports resistance measurements for the
NI 9217.
|
NI 9226
|
FlexLogger supports resistance measurements for the
NI 9226.
|
C Series Universal Analog Input Modules
|
NI 9218
|
For the
NI 9218, all connectivity accessories must be configured in MAX in order to appear in your FlexLogger project.
|
NI 9219
|
FlexLogger supports resistance measurements for the
NI 9219.
|
C Series Strain/Bridge Input Modules
|
NI 9235
|
—
|
NI 9236
|
—
|
NI 9237
|
—
|
C Series Counter Input Module
|
NI 9361
|
FlexLogger supports pull-up resistor functionality and input voltage threshold for the
NI 9361.
|
C Series Digital Modules (serial digital I/O)
|
NI 9375
|
-
The
NI 9375
can only use one port (input or output) at a time in a project.
-
You cannot use parallel and serial modules together on the same FlexLogger project unless they are installed in separate cDAQ chassis.
|
NI 9403
|
NI 9425
|
NI 9426
|
NI 9476
|
NI 9477
|
NI 9478
|
C Series Digital Modules (parallel digital I/O)
|
NI 9344
|
You cannot use parallel and serial modules together on the same FlexLogger project unless they are installed in separate cDAQ chassis.
|
NI 9401
|
NI 9402
|
NI 9411
|
NI 9421
|
NI 9422
|
NI 9423
|
NI 9435
|
NI 9436
|
NI 9437
|
NI 9472
|
NI 9474
|
NI 9475
|
NI 9481
|
NI 9482
|
NI 9485
|
C Series CAN and Vehicle Multiprotocol Interface Modules
|
NI 9860
|
FlexLogger supports all compatible transceiver cables for the
NI 9860
(TRC-8542,
TRC-8543, and
TRC-8546).
|
NI 9861
|
—
|
NI 9862
|
—
|
C Series LIN Interface Module |
NI 9866
|
—
|
Table 3.
FieldDAQ Devices
NI Product |
Model Name
|
Notes |
Voltage Input Devices for FieldDAQ |
FD-11601
|
External powered sensor configuration is supported in FlexLogger.
|
FD-11603
|
Revision B and later of the FD-11603 supports hardware filtering. Refer to the
Reducing Signal Noise
topic for more information.
|
FD-11605 |
— |
Sound and Vibration Input Devices for FieldDAQ |
FD-11634
|
— |
Strain/Bridge Input Devices for FieldDAQ |
FD-11637
|
Revision B and later of the FD-11637 supports hardware filtering. Refer to the
Reducing Signal Noise
topic for more information.
|
Temperature Input Devices for FieldDAQ |
FD-11613
|
— |
FD-11614
|
— |
Note:
FieldDAQ devices support network synchronization using IEEE 802.1AS protocol. Refer to the
Using Network Synchronization in Your Acquisition
topic for more information.
Note:
FieldDAQ devices support hardware filtering. Refer to the
Reducing Signal Noise
topic for more information. (See
Notes
column for exceptions.)
|
Table 4.
PXI Chassis
NI Product |
Notes |
PXIe-1062Q |
FlexLogger does not support any module used in a PXI peripheral slot.
|
PXIe-1065 |
PXIe-1066DC |
PXIe-1071
|
— |
PXIe-1073 |
— |
PXIe-1075 |
— |
PXIe-1078 |
— |
PXIe-1082 |
— |
PXIe-1082DC |
— |
PXIe-1084 |
— |
PXIe-1085 (12 GB/s and 24GB/s) |
— |
PXIe-1092 |
— |
PXIe-1095 |
— |
PXI Controllers
Supported embedded controllers must meet the minimum system requirements. Refer to the
System Requirements
section of the
FlexLogger 2020 R3 Readme
for more information.
Table 5.
PXI Remote Control Modules
NI Product |
Notes |
PXIe-8301 |
— |
PXIe-8360 |
— |
PXIe-8370 |
— |
PXIe-8375 |
— |
PXIe-8381 |
— |
PXIe-8388 |
— |
PXIe-8389 |
— |
PXIe-8394 |
— |
PXIe-8398 |
— |
PXIe-8399 |
— |
Table 6.
PXI Modules
NI Product |
Model Name
|
Compatible Accessories |
Notes |
PXI Analog Input Modules |
PXIe-4300 |
- TB-4300
- TB-4300B
- TB-4300C
|
—
|
PXIe-4302 |
|
—
|
PXIe-4303 |
|
—
|
PXIe-4304 |
|
—
|
PXIe-4305 |
|
—
|
PXIe-4309 |
-
TB-4309 (Mass Termination)
- TB-4309 (Screw Terminal)
|
—
|
PXIe-4310 |
|
—
|
PXIe-4481 |
— |
— |
PXI Strain/Bridge Input Module |
PXIe-4330 |
|
—
|
PXIe-4331 |
|
—
|
PXIe-4339 |
- TB-4339
- TB-4339B
- TB-4339C
- RM-4339
|
—
|
PXI Displacement Input Module |
PXIe-4340 |
|
—
|
PXI Temperature Input Module |
PXIe-4353 |
|
—
|
PXIe-4357 |
|
FlexLogger supports resistance measurements for the
PXIe-4357.
|
PXI Analog Output Module |
PXIe-4322 |
|
—
|
PXI Sound and Vibration Modules |
PXIe-4464 |
—
|
—
|
PXIe-4480 |
—
|
FlexLogger does not support the Charge measurement type. |
PXIe-4492 |
—
|
FlexLogger automatically selects the Medium (100 Hz) data rate for the
PXIe-449x
. Using data rates between
1,000 Hz
and
8,000 Hz
with the
PXIe-449x
may cause delays when configuring channels.
|
PXIe-4496 |
—
|
PXIe-4497 |
—
|
PXIe-4498 |
—
|
PXIe-4499 |
—
|
PXI Vehicle Multiprotocol Interface Module |
PXIe-8510 (2-Port and 6-port)
|
-
TRC-8542
-
TRC-8543
-
TRC-8546
|
—
|
PXI CAN Interface Module |
PXI-8512 (1-port and 2-port) |
—
|
Must be used in a PXIe Hybrid Compatible slot of a supported PXI Express chassis. For additional information on PXI compatibility with PXI Express chassis, visit
ni.com/r/pxicompatibility.
|
PXI LIN Interface Module |
PXI-8516 |
—
|
Note:
The following synchronization considerations apply to PXI modules in FlexLogger:
- FlexLogger supports PXI synchronization between modules in a chassis.
- FlexLogger does not currently support synchronization between multiple chassis or other devices in the system.
|
Table 7.
USB Devices
NI Product |
Model Name
|
Notes |
CAN Interface Devices
|
USB-8502
|
—
|
LIN Interface Devices
|
USB-8506
|
—
|