(ECUTS-16000) Replacing the EPO Panel

Version:
    Last Modified: March 29, 2021

    Equipment

    • #1 Phillips screwdriver
    • #2 Phillips screwdriver
    • Adjustable wrench
    • Hex driver
    1. Power off the ECUTS-16000.
    2. Disconnect the cables from the monitor.
    3. Pull the cable gland and accompanying cables from the fan plate.
    4. Loosen the set screw on the monitor arm using the hex driver.
    5. Lift the monitor arm out of the monitor mount.
    6. Remove the six screws on the fan plate using the #1 Phillips screwdriver.
    7. Move aside the fan plate to expose the top of the test rack.
    8. Disconnect the fan assembly power supply cables from the WAGO nuts.
    9. Remove the #4-40 standoff screws from the safety shutoff thermostats using the hex driver.
    10. Remove the fan plate from the test rack.
    11. Remove the ground cable nut from the PEP using the adjustable wrench.
    12. Remove the ground cable from the PEP.
    13. Disconnect the AC power cable, ethernet cable, and USB cable from the PEP.
    14. Remove the screws securing the USB ports to the PEP using the #2 Phillips screwdriver.
    15. Remove the screws securing the PEP to the test rack using the #2 Phillips screwdriver.
    16. Remove the PEP from the test rack.
    17. Disconnect the ethernet cable from the inside of the PEP.
    18. Disconnect the Molex connecter from the inside of the PEP.
    19. Disconnect the power connecter from the inside of the PEP.
    20. Remove the filler panels above the receiver using the #2 Phillips screwdriver.
    21. Disconnect the cable labeled EDR from the PDU.
    22. Remove the screws from the EPO panel using the #2 Phillips screwdriver.
    23. Remove the EPO panel.
    24. Install the replacement EPO panel.
    25. Replace the screws to the EPO panel using the #2 Phillips screwdriver.
    26. Connect the cable labeled EDR to the PDU.
    27. Replace the filler panels above the receiver using the #1 Phillips screwdriver.
    28. Connect the power connector to the inside of the PEP.
    29. Connect the Molex connector to the inside of the PEP.
    30. Connect the ethernet cable to the inside of the PEP.
    31. Place the PEP into the test rack.
    32. Screw in the screws securing the PEP to the test rack using the #2 Phillips screwdriver.
    33. Screw in the screws securing the USB ports to the PEP using the #2 Phillips screwdriver.
    34. Connect the AC power cable, ethernet cable, and USB cable to the PEP.
    35. Insert the ground cable into the PEP.
    36. Torque the ground cable nut to the PEP using the adjustable wrench to 1.29 N · m (11.5 lb · in.).
    37. Place the fan plate on the top of the test rack.
    38. Screw in the #4-40 standoff screws to the safety shutoff thermostats using the hex driver.
    39. Connect the fan assembly power supply cables to the WAGO nuts.
    40. Screw in the six screws to the top of the fan plate using the #1 Phillips screwdriver.
    41. Place the monitor arm into the monitor mount.
    42. Tighten the set screw on the monitor arm using the hex driver.
    43. Attach the cable gland and accompanying cables to the fan panel.
    44. Connect the cables to the monitor.