    Equipment

    • #1 Phillips screwdriver
    • #2 Philips screwdriver
    • Adjustable wrench
    • Hex driver
    1. Power off the ECUTS-16001
    2. Fold down the keyboard tray.
    3. Remove the filler panels between the keyboard tray and the EPO panel (U23-U25) by unscrewing the screws using the #2 Phillips screwdriver.
    4. Unplug the USB cables routed from the PEP (blue cables) from the PXI controller.
    5. Remove the ground cable nut from the PEP using the adjustable wrench.
    6. Remove the ground cable from the PEP.
    7. Disconnect the facility AC power cable, ethernet cable, and USB cable from the PEP.
    8. Disconnect the internal ground from the PEP grounding plate using the #1 Phillips screwdriver.
    9. Remove the PEP from the test rack.
    10. Connect the power connectors to the inside of the PEP.
    11. Connect the internal ground cable to the PEP grounding plate using the #1 Phillips screwdriver.
    12. Connect the Molex connector from the EPO panel to the inside of the PEP.
    13. Connect the ethernet cable to the inside of the PEP.
    14. Attach the internal ground cable to the PEP ground plate using the #1 Phillips screwdriver.
    15. Place the PEP into the test rack.
    16. Screw in the screws securing the PEP to the test rack using the #2 Phillips screwdriver.
    17. Connect the facility AC power cable, ethernet cable, and USB cable to the PEP.
    18. Attach the ground cable into the PEP ground lug.
    19. Torque the ground cable nut to the PEP using the adjustable wrench to 1.29 N · m (11.5 lb · in.).
    20. Plug the USB cables from the PEP to the PXI controller.
    21. Replace the filler panels on the front of the rack by attaching them with screws using the #2 Phillips screwdriver.