Table Of Contents

ECUTS-16001 Specifications

Version:
    Last Modified: January 26, 2021

    These specifications apply to all ECUTS-16001 configuration options unless otherwise noted.

    Definitions

    Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Warranted specifications account for measurement uncertainties, temperature drift, and aging. Warranted specifications are ensured by design or verified during production and calibration.

    Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

    • Typical specifications describe the performance met by a majority of models.
    • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
    • Measured specifications describe the measured performance of a representative model.

    Specifications are Warranted unless otherwise noted.

    Conditions

    Refer to ni.com/manuals for detailed specifications on the specific instruments used within the ECUTS-16001.

    Specifications are valid for the system and all included instruments under the following conditions unless otherwise noted.

    • ECU Test System environmental characteristics are met
    • Instrument-level conditions are met

    Calibration Conditions

    The performance of an externally calibrated instrument is defined in the instrument specifications. Additionally, specifications for externally calibrated instruments are only valid if the conditions defined in the instrument specifications are met. For applications that require calibrated power measurements, NI recommends using PXI and switch load and signal conditioning (SLSC) instrumentation.

    Physical Characteristics

    Dimensions
    Width

    All configurations

    584 mm (23.0 in.)

    Depth

    Without 9025TR platform[1]

    884 mm (34.8 in.)

    With 9025TR platform

    1,356 mm (53.4 in.)

    Height

    All configurations

    2,068 mm (84.1 in.)

    Weight[2]

    Minimum

    185 kg (407 lb)

    Maximum[3]

    275 kg (606 lb)

    Maximum Allowable Weight Limit

    9025TR platform

    18 kg (40 lb)

    Keyboard tray

    0.9 kg (2 lb)

    Interchangeable test adapter (ITA)[4]

    18 kg (40 lb)

    The circuit breaker on the power entry panel PEP-130 is rated for a mechanical impact energy level of IK06 (1J), when tested with a direct vertical impact per IEC 61010-1, 3rd Ed., Table 15 and Clause 8.2. The circuit breaker should be guarded against impacts exceeding 1J.

    Power Requirements

    Input voltage range

    200 VAC to 240 VAC, 50/60 Hz, single phase, 24 A, maximum

    Input power receptacle

    IEC 60309 2P+E 6H 32 A

    Ground stud size

    M8 x 21 mm

    The ECUTS-16001 shipment contains a power cord that corresponds to your country of operation.

    Maximum Thermal Load

    Minimum rating for internal equipment

    50 °C

    Maximum Allowable Internal Dissipation

    40 °C Ambient

    1,350 W

    28 °C Ambient

    3,400 W

    23 °C Ambient

    4,300 W

    spd-note-note
    Note  

    All equipment inside the rack must be powered, directly or indirectly, through the PEP-130 power entry panel. Other sources of external power must not be used.

    Compressed Air

    Air type

    Clean, dry air

    Connector type

    6 mm outer diameter

    Maximum pressure

    100 PSI

    DC Output

    Table 1. DC Output
    PDU Nominal Voltage Rated Output Current Overcurrent Protection Location[5] and Use Interlock[5]
    DC1 12 V 4 A 20 A Connector J22, pin 1 referenced to pin 2, fixture power Connector J1, short, dry contact between pins B43 and B44
    DC2 24 V 2 A 10 A Connector J22, pin 34 referenced to pin 35, fixture power

    Connector J1, short, dry contact between connectors C43 and C44

    DC3[6] 24 V 5 A 10 A Internal, fans and instrumentation
    DC4 48 V 2 A 5 A Internal, network switch
    RMX-410x (optional)

    Interlock[5]

    Connector J1, short, dry contact between pins A43 and A44

    Maximum total output power

    2,000 W

    I/O

    Network Ports
    External

    Type

    I219

    Standard

    IEEE 802.3 Ethernet, 10BASE-T, 100BASE-TX, 1000BASE-T

    Speed

    10 Mbps, 100 Mbps, 1000 Mbps

    Internal

    Speed

    10 Mbps, 100 Mbps

    Subnet

    169.254.160.xxx

    Number of ports

    15 switched ports (two for the mass interconnect, up to 13 for instrumentation)

    USB Ports
    Rear

    Number of ports

    2

    Type

    USB 3.0

    Internal (optional)

    Number of ports

    7

    Type

    USB 2.0

    Mass Interconnect

    Model

    Virginia Panel Corporation 9025/9025TR

    Environmental Characteristics

    Temperature

    Operating

    5 °C to 40 °C

    Storage

    0 °C to 60 °C

    Humidity

    Operating

    20% to 80%, noncondensing

    Storage

    10% to 80%, noncondensing

    Pollution Degree

    2

    Maximum altitude

    2,000 m

    Hardware Components

    The following components are used within the ECUTS-16001.

    spd-note-note
    Note  

    Detailed specifications for hardware components are available online at ni.com/manuals.

    Table 2. Required Hardware Components
    Model Description

    PXIe-1084[7]

    PXIe-1095

    18-Slot (17 Hybrid Slots), Up to 4 GB/s PXI Chassis

    18-Slot (5 Hybrid Slots, 11 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 24 GB/s PXI Chassis

    PXIe-8861 2.8 GHz Quad-Core Intel Xeon PXI Controller
    RMX-10011 Mid Power 40U Rack with Low Speed Fan Panel
    RMX-10050

    Single Phase PDU

    Single Phase PDU with DC Output

    Table 3. PXI Instruments
    Model Description
    PXI-2520[8] 80-Channel, 2 A, SPST Relay Module
    PXI-2564[8] 16-Channel, 5 A, SPST Relay Module
    PXIe-2527 32-Channel, 2-Wire Multiplexer
    PXIe-2737[8] 4 x 64, 2-Wire Matrix Switch Module
    PXIe-2738[8] 8 x 32, 2-Wire Matrix Switch Module
    PXIe-2739[8] 16 x 16, 2-Wire Matrix Switch Module
    PXIe-4081[8],[9] 7½-Digit Multimeter with 1.8 MS/s Isolated Digitizer
    PXIe-4082[8] 6½-Digit Multimeter with 1.8 MS/s Isolated Digitizer, L and C Measurement Support
    PXIe-4112 2-Channel, 60 V, 1 A Programmable Power Supply
    PXIe-4139 60 V Precision Source Measure Unit
    PXIe-4309 2 MS/s, 28-bit Flexible Resolution Analog Input
    PXIe-4310 with TB-4310 (600V)[8] 8-Channel, 400 kS/s, 16-Bit Isolated Analog Input Module
    PXIe-4322 8-Channel, 250 kS/s, 16-Bit Isolated Analog Output Module
    PXIe-5105 8-Channel, 60 MHz Bandwidth, 12-Bit Oscilloscope
    PXIe-5110 2-Channel, 100 MHz Bandwidth, 8-bit Oscilloscope
    PXIe-5163 2-Channel, 200 MHz Bandwidth, 14-bit Oscilloscope
    PXIe-5413 2-Channel, 20 MHz Bandwidth, 16-Bit Waveform Generator
    PXIe-5433 2-Channel, 80 MHz Bandwidth, 16-bit Waveform Generator
    PXIe-6366 8 AI (16-bit, 2 MS/s/ch), 2 AO, 24 DIO Multifunction I/O Module
    PXIe-6386 8 AI (16-Bit, 14 MS/s/ch), 2 AO, 24 DIO Multifunction I/O Module
    PXI-6515 64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Sink Outputs, Bank-Isolated Digital I/O Module
    PXIe-6738 1 MS/s, 16-bit Analog Output
    PXIe-8430/8 8-Port, RS232 Serial Interface Module
    PXIe-8510 with TRC-8543 or TRC-8546 Transceiver Cable 6-Port Vehicle Multiprotocol Interface Module with CAN or LIN Transceivers
    PXIe-8523 4-Port 100/1000BASE-T1 Automotive Ethernet
    Table 4. Load Switching
    Model Description
    SLSC-12001 12-Slot Chassis for SLSC
    SLSC-12251[8],[10] 16-Channel, 8 A Fault Insertion Module
    SLSC-12252[8],[11] 8-Channel, 30 A Fault Insertion Module
    PXIe-6375 104 AI, 3.8 MS/s, 16-Bit Multifunction I/O Module
    USB-6363 16 AI, 2 MS/s, 16-Bit Multifunction I/O Device
    Table 5. Power Supplies and Electronic Loads
    Model Description
    RMX-4101 20 V, 10 A, Programmable Power Supply Device
    36 V, 6 A, Programmable Power Supply Device
    60 V, 3.5 A, Programmable Power Supply Device
    RMX-4102 20 V, 20 A, Programmable Power Supply Device
    36 V, 12 A, Programmable Power Supply Device
    60 V, 7 A, Programmable Power Supply Device
    RMX-4104 20 V, 40 A Programmable Power Supply Device
    36 V, 24 A Programmable Power Supply Device
    60 V, 14 A Programmable Power Supply Device
    • 1 Depth of the system without the 9025TR platform assumes a folded open keyboard tray.
    • 2 The estimated weight of the system depends on which options are purchased and installed.
    • 3 The weight of an ECUTS-16001 as configured by NI (combined weight of the frame, instrumentation, cabling, monitor, 9025TR platform, and keyboard tray) does not exceed 275 kg (606 lbs). The maximum weight of an ECUTS-16001, including user additions, must not exceed 453 kg (1,000 lbs). Contact NI for more information about the weight of your system.
    • 4 Maximum weight limit when the ITA is attached to the ECUTS-16001 without the 9025TR platform.
    • 5 Refer to the ECUTS-16000/16001 User Manual for more information about connector and pin locations.
    • 6 Reserved for NI internal use only.
    • 7 An optional secondary PXIe-1084 chassis can be added using a PXIe-8301 Thunderbolt™ 3 PXI Remote Control Module.
    • 8 Maximum input voltage in ECUTS-16001: 60 VDC, Measurement Category I.
    • 9 Add ±15 μV to the DC accuracy specifications in the PXIe-4081 Specifications on ni.com/manuals.
    • 10 The maximum allowable current in a SLSC-12251 channel is 8 A.
    • 11 The maximum allowable current in a SLSC-12252 channel is 30 A.

    Recently Viewed Topics