Table Of Contents

ECUTS-16000 Specifications

Version:
    Last Modified: March 24, 2021

    These specifications apply to all ECU Test System configuration options unless otherwise noted.

    Definitions

    Warranted specifications describe the performance of a model under stated operating conditions and are covered by the model warranty. Warranted specifications account for measurement uncertainties, temperature drift, and aging. Warranted specifications are ensured by design or verified during production and calibration.

    Characteristics describe values that are relevant to the use of the model under stated operating conditions but are not covered by the model warranty.

    • Typical specifications describe the performance met by a majority of models.
    • Nominal specifications describe an attribute that is based on design, conformance testing, or supplemental testing.
    • Measured specifications describe the measured performance of a representative model.

    Specifications are Warranted unless otherwise noted.

    Conditions

    Refer to ni.com/manuals for detailed specifications on the specific instruments used within the ECUTS-16000.

    Specifications are valid for the system and all included instruments under the following conditions unless otherwise noted.

    • ECU Test System environmental characteristics are met
    • Instrument-level conditions are met

    Calibration Conditions

    The performance of an externally calibrated instrument is defined in the instrument specifications. Additionally, specifications for externally calibrated instruments are only valid if the conditions defined in the instrument specifications are met. For applications that require calibrated power measurements, NI recommends using PXI and switch load and signal conditioning (SLSC) instrumentation.

    Physical Characteristics

    Dimensions
    Width

    All configurations

    584 mm (23.0 in.)

    Depth

    Without 9025TR platform

    853 mm (33.6 in.)

    With 9025TR platform

    1,650 mm (65.0 in.)

    Height

    With monitor mount, before monitor arm assembly

    1,440 mm (56.5 in.)

    Maximum, with monitor and keyboard tray

    2,080 mm (81.8 in.)

    Weight[1]

    Minimum

    185 kg (407 lb)

    Maximum[2]

    240 kg (529 lb)

    Maximum Allowable Weight Limit

    9025TR platform

    18 kg (40 lb)

    Keyboard tray

    0.9 kg (2 lb)

    Interchangeable test adapter (ITA)[3]

    18 kg (40 lb)

    The circuit breaker on the power entry panel PEP-116 is rated for a mechanical impact energy level of IK06 (1J), when tested with a direct vertical impact per IEC 61010-1, 3rd Ed., Table 15 and Clause 8.2. The circuit breaker should be guarded against impacts exceeding 1J.

    Protective Earthing

    High levels of leakage current may be present on the ECUTS-16000. Connect the ECUTS-16000 protective earth terminal before connecting to AC power.

    spd-note-note
    Note  

    The facility installation shall provide a means for connection to protective earth, and qualified personnel shall install a protective earthing conductor from the ECUTS-16000 protective earthing terminal to the protective earth wire in the facility.

    Protective Earth Terminal Wiring

    Grounding wire

    2.1 mm2 (14 AWG)

    Ring lug

    Size

    M8

    Length

    20 mm (0.8 in.)

    Minimum protective earth terminal torque

    1.29 N · m (11.5 lb · in.)

    Power Requirements

    Input voltage range

    200 VAC to 240 VAC, 50/60 Hz, single phase, 16 A, maximum

    Input power receptacle

    IEC 60320 C20

    The ECUTS-16000 shipment contains a power cord that corresponds to your country of operation.

    Maximum Thermal Load

    Maximum internal temperature

    50 °C

    Maximum Allowable Internal Dissipation

    40 °C Ambient

    1,350 W

    28 °C Ambient

    3,400 W

    23 °C Ambient

    3,790 W

    spd-note-note
    Note  

    All equipment inside the rack must be powered, directly or indirectly, through the power entry panel PEP-116. Other sources of external power must not be used.

    Compressed Air

    Air type

    Clean, dry air

    Connector type

    6 mm outer diameter

    Maximum pressure

    100 PSI

    DC Output

    Table 1. DC Output
    PDU Nominal Voltage Rated Output Current Overcurrent Protection Location[4] and Use Interlock[4]
    DC1 12 V 4 A 20 A Connector J22, pin 1 referenced to pin 2, fixture power Connector J1, short, dry contact between pins B43 and B44
    DC2 24 V 2 A 10 A Connector J22, pin 34 referenced to pin 35, fixture power

    Connector J1, short, dry contact between connectors C43 and C44

    DC3[5] 24 V 5 A 10 A Internal, fans and instrumentation
    DC4 48 V 2 A 5 A Internal, network switch
    RMX-410x (optional)

    Interlock[4]

    Connector J1, short, dry contact between pins A43 and A44

    Maximum total output power

    1,500 W

    I/O

    Network Ports
    External

    Type

    I219

    Standard

    IEEE 802.3 Ethernet, 10BASE-T, 100BASE-TX, 1000BASE-T

    Speed

    10 Mbps, 100 Mbps, 1000 Mbps

    Internal

    Speed

    10 Mbps, 100 Mbps

    Subnet

    169.254.160.xxx

    Number of ports

    15 switched ports (two ports for the mass interconnect, up to 12 for instrumentation)

    USB Ports
    Rear

    Number of ports

    2

    Type

    USB 3.0

    Top

    Number of ports

    1

    Type

    USB 2.0 cable (to monitor hub)

    Internal (optional)

    Number of ports

    7

    Type

    USB 2.0

    Mass Interconnect

    Model

    Virginia Panel Corporation 9025/9025TR

    Environmental Characteristics

    spd-note-notice
    Notice  

    This product is intended for use in indoor applications only.

    Temperature

    Operating

    5 °C to 40 °C

    Storage

    0 °C to 60 °C

    Humidity

    Operating

    20% to 80%, noncondensing

    Storage

    10% to 80%, noncondensing

    Pollution Degree

    2

    Maximum altitude

    2,000 m

    Hardware Components

    The following components are used within the ECUTS-16000.

    spd-note-note
    Note  

    Detailed specifications for hardware components are available online at ni.com/manuals.

    Table 2. Required Hardware Components
    Model Description

    PXIe-1084 or

    PXIe-1095

    18-Slot (17 Hybrid Slots), Up to 4 GB/s PXI Chassis

    18-Slot (5 Hybrid Slots, 11 PXI Express Slots, 1 PXI Express System Timing Slot), Up to 24 GB/s PXI Chassis

    PXIe-8861 2.8 GHz Quad-Core Intel Xeon PXI Controller
    RMX-10011 Low Power 24U Rack with Low Speed Fan Panel
    RMX-10050 Single Phase PDU with DC Output
    Table 3. PXI Instruments
    Model Description
    PXI-2520[6] 80-Channel, 2 A, SPST Relay Module
    PXI-2527[6] 32-Channel, 2-Wire Multiplexer
    PXI-2564[6] 16-Channel, 5 A, SPST Relay Module
    PXIe-2737[6] 4 x 64, 2-Wire Matrix Switch Module
    PXIe-2738[6] 8 x 32, 2-Wire Matrix Switch Module
    PXIe-2739[6] 16 x 16, 2-Wire Matrix Switch Module
    PXIe-4081[6],[7] 7½-Digit Multimeter with 1.8 MS/s Isolated Digitizer
    PXIe-4082[6] 6½-Digit Multimeter with 1.8 MS/s Isolated Digitizer, L and C Measurement Support
    PXIe-4112 2-Channel, 60 V, 1 A Programmable Power Supply
    PXIe-4139 60 V Precision Source Measure Unit
    PXIe-4309 2 MS/s, 28-bit Flexible Resolution Analog Input
    PXIe-4310 with TB-4310 (600V)[6] 8-Channel, 400 kS/s, 16-Bit Isolated Analog Input Module
    PXIe-4322 8-Channel, 250 kS/s, 16-Bit Isolated Analog Output Module
    PXIe-5105 8-Channel, 60 MHz Bandwidth, 12-Bit Oscilloscope
    PXIe-5110 2-Channel, 100 MHz Bandwidth, 8-bit Oscilloscope
    PXIe-5163 2-Channel, 200 MHz Bandwidth, 14-bit Oscilloscope
    PXIe-5413 2-Channel, 20 MHz Bandwidth, 16-Bit Waveform Generator
    PXIe-5433 2-Channel, 80 MHz Bandwidth, 16-bit Waveform Generator
    PXIe-6366 8 AI (16-bit, 2 MS/s/ch), 2 AO, 24 DIO Multifunction I/O Module
    PXIe-6386 8 AI (16-Bit, 14 MS/s/ch), 2 AO, 24 DIO Multifunction I/O Module
    PXI-6515 64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Sink Outputs, Bank-Isolated Digital I/O Module
    PXIe-6738 1 MS/s, 16-bit Analog Output
    PXIe-8430/8 8-Port, RS232 Serial Interface Module
    PXIe-8510 with TRC-8543 or TRC-8546 Transceiver Cable 6-Port Vehicle Multiprotocol Interface Module with CAN or LIN Transceivers
    PXIe-8523 4-Port 100/1000BASE-T1 Automotive Ethernet
    Table 4. Load Switching
    Model Description
    SLSC-12001 12-Slot Chassis for SLSC
    SLSC-12251[6],[8] 16-Channel, 8 A Fault Insertion Module
    SLSC-12252[6],[9] 8-Channel, 30 A Fault Insertion Module
    PXIe-6375 104 AI, 3.8 MS/s, 16-Bit Multifunction I/O Module
    USB-6363 16 AI, 2 MS/s, 16-Bit Multifunction I/O Device
    Table 5. Power Supplies and Electronic Loads
    Model Description
    RMX-4101 20 V, 10 A, Programmable Power Supply Device
    36 V, 6 A, Programmable Power Supply Device
    60 V, 3.5 A, Programmable Power Supply Device
    RMX-4102 20 V, 20 A, Programmable Power Supply Device
    36 V, 12 A, Programmable Power Supply Device
    60 V, 7 A, Programmable Power Supply Device
    RMX-4002 4-Slot Electronic Load Device Mainframe
    RMX-4003[6] 2-Channel, 100 W, Electronic Load Device
    RMX-4005[6],[10] 1-Channel, 350 W, Electronic Load Device
    • 1 The estimated weight of the system depends on which options are purchased and installed.
    • 2 This value reflects the maximum weight of an ECUTS-16000 as configured by NI. The maximum weight of an ECUTS-16000, including user additions, must not exceed 453 kg (1,000 lbs). Contact NI for more information about the weight of your system.
    • 3 Maximum weight limit when the ITA is attached to the ECUTS-16000 without the 9025TR platform.
    • 4 Refer to the ECUTS-16000/16001 User Manual for more information about connector and pin locations.
    • 5 Reserved for NI internal use only.
    • 6 Maximum input voltage in ECUTS-16000: 60 V, Measurement Category I.
    • 7 Add ±15 μV to the DC accuracy specifications in the PXIe-4081 specifications on ni.com/manuals.
    • 8 The maximum allowable current in a SLSC-12251 channel is 8 A.
    • 9 The maximum allowable current in a SLSC-12252 channel is 30 A.
    • 10 The single channel on an RMX-4005 module is routed to two sets of terminals on the mass interconnect. Each load terminal is rated to 40 A max.

    Recently Viewed Topics