Purpose

Executes the UDS ECUReset service. Resets the ECU. Format

Input

diag ref in specifies the diagnostic session handle, obtained from Open Diagnostic on CAN FD.vi or Open Diagnostic on IP.vi and wired through subsequent diagnostic VIs. Normally, it is not necessary to manually manipulate the elements of this cluster.
mode indicates the reset mode:
HexDescription
01hardReset
02keyOffOnReset
03softReset
04enableRapidPowerShutDown
05disableRapidPowerShutDown
error in is a cluster that describes error conditions occurring before the VI executes. If an error has already occurred, the VI returns the value of the error in cluster to error out.
status is TRUE if an error occurred. This VI is not executed when status is TRUE.
code is the error code number identifying an error. A value of 0 means success. A negative value means error: the VI did not execute the intended operation. A positive value means warning: the VI executed intended operation, but an informational warning is returned. For a description of the code, wire the error cluster to a LabVIEW error-handling VI, such as the Simple Error Handler.
source identifies the VI where the error occurred.

Output

diag ref out is a copy of diag ref in. You can wire it to subsequent diagnostic VIs.
power down time returns the minimum standby sequence time that the server remains in the power-down sequence in seconds. A value of FF hex indicates a failure or time not available.
success? indicates successful receipt of a positive response message for this diagnostic service.
error out describes error conditions. If the error in cluster indicated an error, the error out cluster contains the same information. Otherwise, error out describes the error status of this VI.
status is TRUE if an error occurred.
code is the error code number identifying an error. A value of 0 means success. A negative value means error: the VI did not execute the intended operation. A positive value means warning: the VI executed intended operation, but an informational warning is returned. For a description of the code, wire the error cluster to a LabVIEW error-handling VI, such as the Simple Error Handler.
source identifies the VI where the error occurred.

Description

This VI requests the ECU to perform an ECU reset effectively based on the mode parameter value content. The vehicle manufacturer determines when the positive response message is sent.

For further details about this service, refer to the ISO 15765-3 standard.