Frequency Channel Properties (CI)
- Updated2025-10-27
- 1 minute(s) read
Configure counter input (CI) channel properties to measure the frequency of a digital signal.
VeriStand measures the frequency of a digital signal by counting observed edges and performing
a software calculation over a period of time determined by your expected frequency
range.
Note This method uses a
software calculation that may not provide the most reliable accuracy or update
rate. Alternatively, if your DAQ card supports Pulse
Measurement, use values from the Frequency channel located under the
counter channels in System Explorer.
| Property/Section | Description |
|---|---|
| Minimum Value | The minimum value you expect to measure before VeriStand performs any scaling or
calibration. Note The minimum value of frequency determines, and is equal to, the
measurement frequency resolution. The measurement time is equal
to the reciprocal of the minimum frequency value. |
| Maximum Value | The maximum value you expect to measure before VeriStand performs any scaling or calibration. |
| Count Edge | Specifies on which edges of the input
signal to increment or decrement the count:
|
Note For device specific information about the default terminals used for counter
measurements and generations, refer to Connecting Counter Signals.
Related Information
- Pulse Measurement Channel Properties (CI)
Configure counter input (CI) channel properties to measure pulse specifications.