Designing for Migration
- Updated2025-04-28
- 1 minute(s) read
The USB-6423 input multiplexers provide a lot of flexibility when configuring AI terminals. However, simultaneously-sampled mioDAQ devices, such as the USB-6451, have more restrictions on the AI Terminal Configuration and channel scanlist.
Follow these rules to enable migration to simultaneously-sampled mioDAQ devices:
- Only include a channel a single time in a given scan.
- When a specific channel is configured for differential (DIFF) mode, do not use the positive or negative inputs from that same channel for referenced single-ended (RSE) or non-referenced single-ended (NRSE) measurements.
- When performing single-ended measurements, pick a common measurement reference for all channels, either RSE or NRSE.