SVPO Average FFT Spectrum (Complex) VI
Owning Palette: Spectrum Extended Measurements VIs
Converts a frequency power spectrum to an order power spectrum. Use this VI to convert power spectrum results from constant-speed applications.
SVPO RMS Average Power Spectrum (Complex) (1 Ch).vi
![]() |
complex spectrum [EU rms] specifies the complex form of the spectrum. Complex spectra can be converted to magnitude and phase components.
| ||||||||||||
![]() |
weighting mode specifies the weighting mode for averaging. This option is available only when averaging mode is RMS averaging.
|
||||||||||||
![]() |
restart averaging specifies if the selected averaging process has to be restarted. The default is FALSE. When you call this VI for the first time, the averaging process restarts automatically. | ||||||||||||
![]() |
average power spectrum [EU^2 rms] returns the calculated average power spectrum.
| ||||||||||||
![]() |
spectrum info returns information about the spectrum needed by the Spectrum Extended Measurements VIs, the Display VIs, and the Tone and Distortion VIs.
|
||||||||||||
![]() |
averages completed out returns the number of averages completed by the VI at that time. |
SVPO RMS Average Power Spectrum (Complex) (N Ch)
![]() |
complex spectrum [EU rms] specifies the complex form of the spectrum. Complex spectra can be converted to magnitude and phase components.
| ||||||||||||
![]() |
weighting mode specifies the weighting mode for averaging. This option is available only when averaging mode is RMS averaging.
|
||||||||||||
![]() |
restart averaging specifies if the selected averaging process has to be restarted. The default is FALSE. When you call this VI for the first time, the averaging process restarts automatically. | ||||||||||||
![]() |
average power spectra [EU^2 rms] returns the power spectra average for each channel. | ||||||||||||
![]() |
spectrum info returns information about the spectrum needed by the Spectrum Extended Measurements VIs, the Display VIs, and the Tone and Distortion VIs.
|
||||||||||||
![]() |
averages completed out returns the number of averages completed by the VI at that time. |
SVPO RMS Average Power Spectrum (Complex) with IC
![]() |
complex spectrum [EU rms] specifies the complex form of the spectrum. Complex spectra can be converted to magnitude and phase components.
| ||||||||||||
![]() |
weighting mode specifies the weighting mode for averaging. This option is available only when averaging mode is RMS averaging.
|
||||||||||||
![]() |
average power spectrum in specifies the previous average spectrum. Do not modify the average spectrum between calls to this VI, as this may produce invalid results. | ||||||||||||
![]() |
averages completed in specifies the number of averages for average spectrum in. | ||||||||||||
![]() |
restart averaging specifies if the selected averaging process has to be restarted. The default is FALSE. When you call this VI for the first time, the averaging process restarts automatically. | ||||||||||||
![]() |
spectrum info returns information about the spectrum needed by the Spectrum Extended Measurements VIs, the Display VIs, and the Tone and Distortion VIs.
|
||||||||||||
![]() |
average power spectrum out returns the updated average power spectrum in units of EU^2 rms. | ||||||||||||
![]() |
averages completed out returns the number of averages completed by the VI at that time. |
SVPO Vector Average Spectrum (Complex) (1 Ch)
![]() |
complex spectrum [EU rms] specifies the complex form of the spectrum. Complex spectra can be converted to magnitude and phase components.
| ||||||||||||
![]() |
weighting mode specifies the weighting mode for averaging. This option is available only when averaging mode is RMS averaging.
|
||||||||||||
![]() |
restart averaging specifies if the selected averaging process has to be restarted. The default is FALSE. When you call this VI for the first time, the averaging process restarts automatically. | ||||||||||||
![]() |
average complex spectrum [EU rms] returns the average of the complex form of the computed spectrum. | ||||||||||||
![]() |
averages completed returns the number of averages completed by the VI at that time. |
SVPO Vector Average Spectrum (Complex) (N Ch)
![]() |
complex spectra [EU rms] returns the complex form of the FFT spectra. | ||||
![]() |
weighting mode specifies the weighting mode for averaging. This option is available only when averaging mode is RMS averaging.
|
||||
![]() |
restart averaging specifies if the selected averaging process has to be restarted. The default is FALSE. When you call this VI for the first time, the averaging process restarts automatically. | ||||
![]() |
average complex spectra [EU rms] returns the average of the complex form of the computed spectra. | ||||
![]() |
averages completed returns the number of averages completed by the VI at that time. |
SVPO Vector Average Spectrum (Complex) with IC
![]() |
complex spectrum [EU rms] specifies the complex form of the spectrum. Complex spectra can be converted to magnitude and phase components.
| ||||||||||||
![]() |
weighting mode specifies the weighting mode for averaging. This option is available only when averaging mode is RMS averaging.
|
||||||||||||
![]() |
average complex spectrum in specifies the initial frequency resolution for the complex spectrum. | ||||||||||||
![]() |
averages completed in specifies the number of averages for average spectrum in. | ||||||||||||
![]() |
restart averaging specifies if the selected averaging process has to be restarted. The default is FALSE. When you call this VI for the first time, the averaging process restarts automatically. | ||||||||||||
![]() |
average complex spectrum out returns the average of the complex form of the computed spectrum. | ||||||||||||
![]() |
averages completed out returns the number of averages completed by the VI at that time. |