niRFSG Properties

Table of Contents

IQ Impairment:I Offset Property

  • Updated2025-02-03
  • 1 minute(s) read

IQ Impairment:I Offset Property

Short Name: I Offset

Property of niRFSG

When using an NI AWG module or vector signal transceiver (VST) device, this property specifies the I-signal DC offset. Units are either percent (%) or volts (V), depending on the Offset Units property setting.

PXIe-5673/5673E: Actual AWG signal offset is equal to the I/Q modulator offset correction plus the value specified by this property. When using an external AWG (non-NI AWG), this property is read-only and indicates the I/Q modulator I-offset. Units are volts, as specified by the Offset Units property.

Supported Devices: PXIe-5644/5645/5646, PXIe-5673/5673E, PXIe-5820/5830/5831/5832/5840/5841/5842

Valid Values: -100% to 100% or -0.2 V to 0.2 V

Related Topics

Impairment Calibration

Remarks

The following table lists the characteristics of this property.

Datatype fD
PermissionsRead/Write
High-level VIs N/A
Channel-based No
ResettableYes