Signal Path:Advanced:Input Isolation Enabled Property
- Updated2025-02-03
- 1 minute(s) read
Signal Path:Advanced:Input Isolation Enabled Property
Short Name: Input Isolation Enabled
Property of niRFSA
Specifies whether input isolation is enabled.
Enabling this property isolates the input signal at the RF IN connector on the RF downconverter from the rest of the RF downconverter signal path. Disabling this property reintegrates the input signal into the RF downconverter signal path.
![]() |
Note If you enable input isolation for your device, the device impedance is changed from the characteristic 50 Ω impedance. A change in the device impedance may also cause a VSWR value higher than the device specifications. |
For the PXIe-5830/5831/5832, input isolation is supported for all available ports for your hardware configuration.
Default Value: Disabled
Supported Devices: PXIe-5601/5603/5605/5606 (external digitizer mode), PXIe-5644/5645/5646, PXIe-5663/5663E/5665/5667/5668, PXIe-5693, PXIe-5820/5830/5831/5832/5840/5841/5842/5860
Disabled (1900) |
The property is disabled. |
Enabled (1901) |
The property is enabled. |
Remarks
The following table lists the characteristics of this property.
Datatype | ![]() |
Permissions | Read/Write |
High-level VIs | N/A |
Channel-based | No |
Resettable | Yes |