Specifies which external trigger line distributes the synchronized Start Trigger signal.

Syntax

NIRFSA_ATTR_SYNC_START_TRIGGER_DIST_LINE

Numeric Value

Data Type

Access

Applies To

1150177

ViString

Read/Write

N/A

Remarks


When synchronizing the Start Trigger, configure all devices to use the same Start Trigger distribution line.

Refer to the Synchronization Using NI-RFSA and NI-RFSG topic appropriate to your device in the NI RF Vector Signal Analyzers Help for more information about device synchronization for vector signal transceivers.

Valid Values: PXI_Trig0, PXI_Trig1, PXI_Trig2, PXI_Trig3, PXI_Trig4, PXI_Trig5, PXI_Trig6, PXI_Trig7, PFI0

Default Value: "" (empty string)

Supported Devices: PXIe-5644/5645/5646