Configures the mask type for the SEM measurement.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default value is "" (empty string).

    Example:

    ""

    "signal::sig1"

    You can use the RFmxWLAN Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI or the RFmxInstr Initialize NIRFSA (Array) VI.

  • ci32.png Mask Type

    Mask Type specifies whether the mask used for the SEM measurement is as per the 3GPP standard or specified by you. The default value is Standard.

    Standard (0)

    Mask limits are configured as per the standard.

    Custom (1)

    Mask limits are configured by you.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference of your RFmx session to the next VI.

  • ierrcodeclst.png error out