Fetches the spectrum used for the SEM measurement.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and result name. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string).

    Example:

    "signal::sig1"

    "result::r1"

    "signal::sig1/result::r1"

    You can use the RFmxWCDMA Build Signal String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the time for which the VI waits for the measurement to complete. This value is expressed in seconds. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • icclst.png Spectrum (dBm)

    Spectrum returns the trace of power levels in the spectral domain.

  • idbl.png x0

    x0 returns the start frequency. This value is expressed in Hz.

  • idbl.png dx

    dx returns the frequency bin spacing. This value is expressed in Hz.

  • i1dsgl.png y

    y returns an array of averaged powers measured at each frequency bin. The value is expressed in dBm.

  • icclst.png Relative Mask (dB)

    Relative Mask returns the trace of power levels representing the relative mask in the spectral domain.

  • idbl.png x0

    x0 returns the start frequency. This value is expressed in Hz.

  • idbl.png dx

    dx returns the frequency bin spacing. This value is expressed in Hz.

  • i1dsgl.png y

    y returns an array of power levels for relative mask. The value is expressed in dBm.

  • icclst.png Absolute Mask (dBm)

    Absolute Mask returns the trace of power levels representing the absolute mask in the spectral domain.

  • idbl.png x0

    x0 returns the start frequency. This value is expressed in Hz.

  • idbl.png dx

    dx returns the frequency bin spacing. This value is expressed in Hz.

  • i1dsgl.png y

    y returns an array of power levels for absolute mask. This value is expressed in dBm.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.