Fetches the relative code domain errors (RCDE) trace of a carrier for the ModAcc measurement.

Use "carrier<n>" as the selector string to read results from this VI.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name, result name, and carrier number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "carrier0".

    Example:

    "carrier0"

    "signal::sig1/carrier0"

    "result::r1/carrier0"

    "signal::sig1/result::r1/carrier0"

    You can use the RFmxWCDMA Build Carrier String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout specifies the time for which the VI waits for the measurement to complete. This value is expressed in seconds. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference to your RFmx session to the next VI.

  • i1dsgl.png RCDE (dB)

    RCDE returns an array of RCDE values of the active channels.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.