Specifies the number of Spurs that the measurement should report in the frequency range.

Use "range< n >" as the selector string to configure this VI.

Supported devices: PXIe-5665, PXIe-5668


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and range number. If you do not specify the signal name, the default signal instance is used. The default value is "range0".

    Example:

    "range0"

    "signal::sig1/range0"

    You can use the RFmxSpecAn Build Range String2 VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • ci32.png Number of Spurs to Report

    Number of Spurs to Report specifies the number of Spurs that the measurement should report in the frequency range. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference of your RFmx session to the next VI.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.