Gets whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the adjacent channel power (ACP) measurement.

Syntax

Namespace: NationalInstruments.RFmx.SpecAnMX

public int GetIFOutputPowerOffsetAuto(string selectorString, out RFmxSpecAnMXAcpIFOutputPowerOffsetAuto value)

Remarks

This method maps to the RFmxSpecAn_ACPGetIFOutputPowerOffsetAuto() function in C.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueout RFmxSpecAnMXAcpIFOutputPowerOffsetAuto

Upon return, indicates whether the measurement computes an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement.

Returns