Groups

Group members

NameDescription
RFmxSpecAn_ACPCfgAveraging

Configures averaging for the adjacent channel power (ACP) measurement.

RFmxSpecAn_ACPCfgCarrierAndOffsets

Configures a carrier channel with offset channels on both sides of the carrier as specified by the number of offsets. The offset channels are separated by +/- n * channel spacing from the center of the carrier. Power is measured over the integration bandwidth for each channel.

RFmxSpecAn_ACPCfgCarrierFrequency

Configures the center frequency of the carrier, relative to the RF center frequency.
Use "carrier<       <i>         n       </i>        >" as the selector string to configure this function.

RFmxSpecAn_ACPCfgCarrierIntegrationBandwidth

Configures the frequency range, in Hz, over which the measurement integrates the carrier power. Use "carrier<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgCarrierMode

Configures whether to consider the carrier power as part of total carrier power measurement. Use "carrier<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgCarrierRrcFilter

Configures the root-raised-cosine (RRC) filter to apply on the carrier channel before measuring the carrier channel power. Use "carrier<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgDetector

Configures the detector settings, including detector type and the number of points to be detected.

RFmxSpecAn_ACPCfgFFT

Configures window and FFT to obtain a spectrum for the adjacent channel power (ACP) measurement.

RFmxSpecAn_ACPCfgMeasurementMethod

Configures the method for performing the adjacent channel power (ACP) measurement.

RFmxSpecAn_ACPCfgNoiseCompensationEnabled

Configures compensation of the channel powers for the inherent noise floor of the signal analyzer.

RFmxSpecAn_ACPCfgNumberOfCarriers

Configures the number of carriers for the adjacent channel power (ACP) measurement.

RFmxSpecAn_ACPCfgNumberOfOffsets

Configures the number of offsets for the adjacent channel power (ACP) measurement.

RFmxSpecAn_ACPCfgOffset

Configures an offset channel on one or both sides of carrier with center to center spacing as specified by the offset frequency and offset frequency definition. In case of multiple carriers, offset frequency is relative to the closest carrier.
Use "offset<        <i>         n       </i>        >" as the selector string to configure this function.

RFmxSpecAn_ACPCfgOffsetFrequencyDefinition

Configures the offset frequency definition for the ACP measurement. Use "offset<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgOffsetIntegrationBandwidth

Configures the frequency range, in Hz, over which the measurement integrates the offset channel power. Use "offset<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgOffsetPowerReference

Configures the power reference to use for measuring the relative power of the offset channel.
Use "offset<        <i>         n       </i>        >" as the selector string to configure this function.

RFmxSpecAn_ACPCfgOffsetRelativeAttenuation

Configures the attenuation, in dB, relative to the external attenuation. Use "offset<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgOffsetRrcFilter

Configures the root raised cosine (RRC) channel filter to be applied on the offset channel before measuring channel power. Use "offset<n>" as the selector string to configure this function.

RFmxSpecAn_ACPCfgPowerUnits

Configures the units for the absolute power.

RFmxSpecAn_ACPCfgRBWFilter

Configures the resolution bandwidth (RBW) filter.

RFmxSpecAn_ACPCfgSweepTime

Configures the sweep time.

RFmxSpecAn_ACPValidateNoiseCalibrationData

Indicates whether calibration data is valid for the configuration specified by the signal name in the Selector string parameter.