RFMXSPECAN_ATTR_TXP_THRESHOLD_ENABLED
- Updated2025-04-08
- 1 minute(s) read
Specifies whether to enable thresholding of the acquired samples to be used for the TXP measurement.
Syntax
RFMXSPECAN_ATTR_TXP_THRESHOLD_ENABLED
Numeric Value | Data Type | Access | Applies To |
---|---|---|---|
1093644 | int32 | Read/Write | N/A |
Remarks
You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.
The default value is False.
Name | Value | Description |
---|---|---|
RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_FALSE | 0 (0x0) | All the acquired samples are considered for the TXP measurement. |
RFMXSPECAN_VAL_TXP_THRESHOLD_ENABLED_TRUE | 1 (0x1) | The samples above the threshold level specified in the RFMXSPECAN_ATTR_TXP_THRESHOLD_LEVEL attribute are considered for the TXP measurement. |