Fetches the multiple measurement points stability trace.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a selector string comprising of the signal name and result name. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "" (empty string).

    Example:

    ""

    "signal::sig1"

    "result::r1"

    "signal::sig1/result::r1"

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

  • cdbl.png Timeout (s)

    Timeout (s) specifies the timeout, in seconds, for fetching the specified measurement. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. The default value is 10.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference of your RFmx session to the next VI.

  • icclst.png Pulse Average Amplitude Stability (dB)

    Pulse Average Amplitude Stability (dB) returns the pulse average amplitude stability trace at multiple measurement points. This value is expressed in dB.

  • idbl.png x0

    x0 returns the start time of measurement window, in seconds.

  • idbl.png dx

    dx returns the sample duration of measurement window, in seconds.

  • i1dsgl.png y

    y returns the average amplitude stability of multiple measurement points, in dB.

  • icclst.png Pulse Average Phase Stability (dB)

    Pulse Average Phase Stability (dB) returns the pulse average phase stability trace at multiple measurement points. This value is expressed in dB.

  • idbl.png x0

    x0 returns the start time of measurement window, in seconds.

  • idbl.png dx

    dx returns the sample duration of measurement window, in seconds.

  • i1dsgl.png y

    y returns the average phase stability of multiple measurement points, in dB.

  • icclst.png Pulse Average Total Stability (dB)

    Pulse Average Total Stability (dB) returns the pulse average total stability trace at multiple measurement points. This value is expressed in dB.

  • idbl.png x0

    x0 returns the start time of measurement window, in seconds.

  • idbl.png dx

    dx returns the sample duration of measurement window, in seconds.

  • i1dsgl.png y

    y returns the average total stability of multiple measurement points, in dB.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.