RFmxPulse Abort Measurements VI
- Updated2025-10-13
- 2 minute(s) read
Stops acquisition and measurements associated with signal instance that you specify in the Selector String parameter, which were previously initiated by the RFmxPulse Initiate VI or measurement read VIs. Calling this VI is optional, unless you want to stop a measurement before it is complete. This VI executes even if there is an incoming error.

Inputs/Outputs
Selector String
—
Selector String specifies the signal name and result name. The result name can either be specified through this input or the Result Name parameter. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name in this parameter, either the result name specified by the Result Name parameter or the default result instance is used. The default value is "" (empty string). Example: "" "signal::sig1" "result::r1" "signal::sig1/result::r1"
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference of your RFmx session to the next VI.
error out
—
error out contains error information. This output provides standard error out functionality. |
Selector String
—
Instrument Handle In
—
error in (no error)
—
Instrument Handle Out
—
error out
—