RFmxNRMXSemUplinkMaskType Enumeration
- Updated2025-10-13
- 4 minute(s) read
Specifies the spectrum emission mask used in the measurement for uplink. You must set the mask type to Custom to configure the custom offset masks. Refer to section 6.5.2 of the 3GPP 38.101 specification for more information about standard-defined mask types.
Syntax
Namespace: NationalInstruments.RFmx.NRMX
public enum RFmxNRMXSemUplinkMaskType
Members
| Name | Value | Description |
|---|---|---|
| General | 0 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.2-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification, Table 6.5.2.1-1 and 6.5A.2.1-1 in section 6.5.2 of the 3GPP TS 38.101-2 specification and Table 6.5B.2.1.1-1 in section 6.5B of the 3GPP TS 38.101-3 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.1.5-1, 6.6.2.1.5-2, 6.6.2.1A.1.5-1, and 6.6.2.1A.1.5-2 in section 6.6.2 of the 3GPP TS 36.521-1 specification.If the band value is set to 46 or 96 or 102, the measurement selects the offset frequencies and limits for SEM as defined in Table 6.5F.2.2-1 in section 6.5F.2 of the 3GPP TS 38.101-1 Specification.If the band value is set to NTN bands 252, 254, 255 or 256, the measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.2.1 in section 6.5.2 of the 3GPP 38.101-5 specification. |
| NS35 | 1 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.1-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification and Table 6.5B.2.1.2.1-1 in section 6.5B of the 3GPP TS 38.101-3 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.5.5-1 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| Custom | 2 | You need to configure the SetNumberOfOffsets(string, int), SetOffsetStartFrequency(string, double), SetOffsetStopFrequency(string, double), SetOffsetAbsoluteLimitStart(string, double), SetOffsetAbsoluteLimitStop(string, double), SetOffsetSideband(string, RFmxNRMXSemOffsetSideband), SetOffsetRbwFilterBandwidth(string, double), SetOffsetRbwFilterType(string, RFmxNRMXSemOffsetRbwFilterType), and SetOffsetBandwidthIntegral(string, int) properties for each offset. |
| NS03 | 3 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.3-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.5.1-1 and 6.6.2.2.5.1-2 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| NS04 | 4 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.2-3 in section 6.5.2 of the 3GPP TS 38.101-1 specification. Subcarrier spacing can be configured through SetBandwidthPartSubcarrierSpacing(string, double) method. Subcarrier spacing corresponding to first bandwidth part is used for computing mask. Transform precoding can be configured through SetPuschTransformPrecodingEnabled(string, RFmxNRMXPuschTransformPrecodingEnabled) method. Transform precoding corresponding to first bandwidth part is used for computing mask. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.3.2-3 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| NS06 | 5 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.4-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.5.3-1 and 6.6.2.2.5.3-2 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| NS21 | 6 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.3-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.5.1-1 and 6.6.2.2.5.1-2 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| NS27 | 7 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.8-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. In case of intra-band contiguous CA consisting of at least one subblock with all NR carriers, for the NR subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.2A.2.3.2.1-1 in section 6.5A.2.3 of the 3GPP TS 38.101-1 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.3.4-1 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| NS07 | 8 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.4-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. In case of non-contiguous EN-DC consisting of at least one subblock with all E-UTRA carriers, for the E-UTRA subblock, the measurement selects the offset frequencies and limits for the SEM, as defined in Table 6.6.2.2.5.3-1 and Table 6.6.2.2.5.3-2 in section 6.6.2 of the 3GPP TS 36.521-1 specification. |
| NS03U | 9 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.3-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. |
| NS21Rel17Onwards | 10 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.9-1 in section 6.5.2 of the 3GPP TS 38.101-1 specification. |
| NS04N | 11 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.1-1 in section 6.5.2.3 of the 3GPP TS 38.101-5 specification. |
| NS05N | 12 | The measurement selects the offset frequencies and limits for SEM as defined in Table 6.5.2.3.2-1 in section 6.5.2.3 of the 3GPP TS 38.101-5 specification. |