SetPuschDmrsNscid(string, int)
- Updated2025-10-13
- 1 minute(s) read
Sets the value of PUSCH DMRS nSCID used for reference signal generation. This method is valid only when you set the SetPuschTransformPrecodingEnabled(string, RFmxNRMXPuschTransformPrecodingEnabled) method to False.
Syntax
Namespace: NationalInstruments.RFmx.NRMX
public int SetPuschDmrsNscid(string selectorString, int value)
Remarks
This method sets the value of PuschDmrsNscid attribute.The default value is 0.
Parameters
| Name | Type | Description |
|---|---|---|
| selectorString | string | Specifies the subblock number, carrier number, bwp number, user number and pusch number. |
| value | int | Specifies the value of PUSCH DMRS nSCID used for reference signal generation. This method is valid only when you set the SetPuschTransformPrecodingEnabled(string, RFmxNRMXPuschTransformPrecodingEnabled) method to False. |
Returns
Returns the status code of this method. The status code either indicates success or describes a warning condition.